Viessmann Vitotrol 100 UTDB-RF2 Installation And Service Instructions Manual

Viessmann Vitotrol 100 UTDB-RF2 Installation And Service Instructions Manual

Room temperature controller with digital time switch and wireless receiver
Hide thumbs Also See for Vitotrol 100 UTDB-RF2:

Advertisement

VIESMANN
Installation and service
instructions
for contractors
Vitotrol 100
Type UTDB-RF2
Room temperature controller with digital time switch
and wireless receiver
for Vitodens 050-W
For applicability, see the last page
VITOTROL 100
Please keep safe.
5461 060 GB
1/2014

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann Vitotrol 100 UTDB-RF2

  • Page 1 VIESMANN Installation and service instructions for contractors Vitotrol 100 Type UTDB-RF2 Room temperature controller with digital time switch and wireless receiver for Vitodens 050-W For applicability, see the last page VITOTROL 100 Please keep safe. 5461 060 GB 1/2014...
  • Page 2: Safety Instructions

    Safety instructions Safety instructions Please follow these safety instructions closely to prevent accidents and mate- rial losses. Safety instructions explained ■ The Code of Practice of relevant trade associations Danger ■ All current safety regulations as This symbol warns against the defined by DIN, EN, DVGW, TRGI, risk of injury.
  • Page 3 Safety instructions Safety instructions (cont.) If you smell flue gas Danger The simultaneous operation of Danger the boiler and appliances that Flue gas can lead to life threat- extract air to the outside can ening poisoning. result in life threatening poison- ■...
  • Page 4 Please note Repairing components that fulfil a safety function can compromise the safe operation of the sys- tem. Faulty components must be replaced with original Viessmann spare parts. Auxiliary components, spare and wearing parts Please note Spare and wearing parts that...
  • Page 5: Table Of Contents

    Index Index Installation instructions Preparing for installation Function........................ Installation site...................... Installation sequence Installing and connecting the wireless receiver............ Installing the Vitotrol 100..................Service instructions Commissioning Commissioning the Vitotrol 100................12 Commissioning the wireless receiver..............12 Service settings Changing the address code................. 14 Specification.......................
  • Page 6: Preparing For Installation

    Preparing for installation Function The Vitotrol 100 type UTDB-RF2 main- tains a constant room temperature by means of its integral room temperature sensor in conjunction with the wireless receiver. During the selected periods, there is a changeover between operation with standard room temperature "Com- fort"...
  • Page 7: Installation Sequence

    Installation sequence Installing and connecting the wireless receiver Installing the wireless receiver Opening the control unit enclosure and connecting the wireless receiver Please note Electronic assemblies can be damaged by electrostatic dis- charge. Prior to commencing any work, touch earthed objects such as heating or water pipes to dis- charge static loads.
  • Page 8 Installation sequence Installing and connecting the wireless receiver (cont.) Insert the wireless receiver cable into the Note control unit enclosure and push the plug Route the lead in such a way that it does into "X5". The plug must click home. not become trapped as the control unit enclosure is closed.
  • Page 9: Installing The Vitotrol 100

    Installation sequence Installing the Vitotrol 100 Opening the Vitotrol 100 Fitting the wall mounting base Always check reception prior to fitting Power is supplied by batteries (see to the wall (see page 13). chapter "Specification").
  • Page 10 Installation sequence Installing the Vitotrol 100 (cont.)
  • Page 11 Installation sequence Installing the Vitotrol 100 (cont.) Assembling the Vitotrol 100...
  • Page 12: Commissioning

    Commissioning Commissioning the Vitotrol 100 1. Open the hinged flap. 2. Use a pointed object to press "Reset". 3. Select language with / . 4. Confirm with OK. 5. Set current date and time with / . 6. Confirm with OK. Commissioning the wireless receiver Several Vitotrol 100 and the wireless receiver can be installed in one building.
  • Page 13 Commissioning Commissioning the wireless receiver (cont.) Testing the strength of reception 1. Press and hold B on the wireless 6. Select "Service" with / . receiver (see diagram on page 12) for 7. Press OK four times to confirm. approx. 5 s until LED flashes.
  • Page 14: Service Settings

    Service settings Changing the address code Change the address code if the wireless connection between the Vitotrol 100 and the wireless receiver fails. 1. Press and hold B on the wireless receiver (see diagram on page 12) for approx. 10 s until LED r flashes. 2.
  • Page 15: Specification

    Specification Specification Vitotrol 100 Rated voltage 3 V– 2 batteries LR 6/AA Ambient temperature ■ during operation 0 to 40 °C ■ during storage and transport −25 to +60 °C IP rating IP 20 to EN 60529 Safety category II to EN 60730-1 Radio frequency 868 MHz Wireless receiver...
  • Page 16: Declaration Of Conformity

    Declaration of Conformity Declaration of Conformity We, Viessmann Werke GmbH&Co KG, D-35107 Allendorf, declare as sole respon- sible body that the product Vitotrol 100, type UTDB-RF2 complies with the following standards: EN 60730-1: 2000+A1: 2004+A12: 2003+A13: 2004+A14: 2005+A16: 2007+A2: 2008...