Data Communication/ Bus - Viessmann SCU224 User Manual

Temperature controller
Table of Contents

Advertisement

SCU224
R1
1 (1) A (
1
(1) A (100 ... 240) V~
R2
N
12
13
14
15
Grounding and load terminals
Temp. Sensor
Pt1000
S1
S2
1
2
3
4
5
Sensor terminals S1 ... S4

1.3 Data communication/ Bus

VBus
®
connection terminals
100 ... 240) V~
R2
N
R1
N
L
16
17
18
19
20
S3
S4
6
7
8
Connecting the device to the power supply must always be
the last step of the installation!
The power supply to the controller must be carried out via
an external power switch (last step!). The supply voltage
must be 100 ... 240 V~ (50 ... 60 Hz). Flexible cables must
be attached to the housing with the enclosed strain relief
and the corresponding screws.
The controller is equipped with two semiconductor re-
lays, to which loads such as pumps, valves etc. can be
connected:
Relay 1
18 = conductor R1
17 = neutral conductor N
13 = ground conductor
Relay 2
16 = conductor R2
15 = neutral conductor N
14 = ground conductor
The power supply is to be carried out at the terminals:
19 = neutral conductor N
20 = conductor L
12 = ground terminal
The temperature sensors (S1 up to S4) are to be
connected to the following terminals with either polarity:
1 / 2 = Sensor 1 (e.g. Sensor collector 1)
3 / 4 = Sensor 2 (e.g. Sensor tank 1)
5 / 6 = Sensor 3 (e.g. Sensor tank top)
7 / 8 = Sensor 4 (e.g. Sensor return)
All Pt1000 temperature sensors are equipped with a
platinum measuring element in their tip. The electrical
resistance of the measuring element changes in relation
to the temperature (see table in chap. 5).
The difference between FKP and FRP type sensors only
lies in the cable insulation material. The insulation material
of FKP type sensor cables resists a higher temperature, so
that FKP type sensors should be used as collector sensors.
FRP type sensors are best used as reference sensors in
tanks or pipes.
The controller is equipped with a VBus
with and energy supply to external modules. The connec-
tion is carried out at the terminals marked "VBus" (either
polarity). One or more VBus
via this data bus, such as
GA3 large display, SD3 smart display
DL2 datalogger
VBus
/USB or VBus
/LAN interface adapter
®
®
VBus
/PWM interface adapter
®
AM1 alarm module
WMZ calorimeter module
By means of a DL2 datalogger or an interface adapter,
the controller can be connected to a PC or a computer
network. With the ServiceCenter Software (RSC) the
controller measurements can be read out, processed and
visualized. The software allows easy function control of the
system. For the remote parametrisation of the controller, a
special software tool will be available for download, soon.
®
for data transfer
modules can be connected
®
5
|