System Layout 8 - Viessmann SCU224 User Manual

Temperature controller
Table of Contents

Advertisement

SCU224

System layout 8

The controller calculates the temperature difference bet-
ween collector sensor S1 and tank sensor S2. If the diffe-
rence is larger than or identical to the adjusted switch-on
temperature difference (DT O), the solar pump will be
operated by relay 1, and the tank will be loaded until the
switch-off temperature difference (DT F) or the maximum
tank temperature (S MX) is reached.
Arr 8
S1
R1
Display Channels
Channel
Description
x*
INIT
ODB initialization active
FLL
x*
ODB filling time active
x*
STAB
ODB stabilization in progress
COL
x
Temperature collector
TSTB
x
Temperature tank 1 bottom
TSTT
x
Temperature tank 1 at the top
TSFB
x
Temperature solid fuel boiler
n1 %
x
Pump speed R1
n2 %
x
Pump speed R2
h P1
x
Operating hours R1
h P2
x
Operating hours R2
TIME
x
Time
24
|
A solid fuel boiler will be operated by relay 2, if the tempera-
ture difference between sensors S4 and S3 is larger than or
identical to the adjusted switch-on temperature difference
(DT3O), until the adjusted minimum (MN3O) and maximum
(MX3O) temperature thresholds of the fuel boiler and the
tank are reached.