System Layout 6 - Viessmann SCU224 User Manual

Temperature controller
Table of Contents

Advertisement

SCU224

System layout 6

The controller calculates the temperature differences
between collector sensor S1 and tank sensors S2 and S3. If
the differences are larger than or identical to the adjusted
switch-on temperature differences (DT1O / DT2O), the
solar pumps will be operated by relay 1 and / or relay 2,
and the respective tank will be loaded until the switch-off
temperature differences (DT1F / DT2F) or the maximum
Arr 6
S1
S4
R1
R2
Display Channels
Channel
Description
COL
x
Temperature collector
TST1
x
Temperature tank 1 bottom
TST2
x
Temperature tank 2 bottom
S4
x
Temperature sensor 4
n1 %
x
Pump speed R1
n2 %
x
Pump speed R2
h P1
x
Operating hours R1
h P2
x
Operating hours R2
TIME
x
Time
20
|
tank temperatures (S1MX / S2MX) are reached. The priority
logic causes priority loading of the selected tank (PRIO), if
possible. Loading both tanks simultaneously is possible as
well (PRIO = 0).
Sensor S4 can optionally be connected for measurement
purposes.
Tank 1
S2
Tank 2
S3
Terminal
Page
S1
37
S2
37
S3
37
S4
37
R1
38
R2
38
R1
38
R2
38
-
34