Indoor Unit Installation - Daikin J-Series Engineeiring Data

J-series split cooling only / heat pump
Hide thumbs Also See for J-Series:
Table of Contents

Advertisement

EDUS041016

Indoor Unit Installation

1.
Installing the mounting plate
• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the plate is completely level, and mark the boring
points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions
2-9/64
(54.5)
Room Air Conditioners J-Series
Recommended mounting plate
retention spots (5 spots in all)
(Bolt size: 3/8 (M10))
4-47/64
7-63/64
(120.5)
(203)
6-19/64
1-31/32
(160)
(50)
13-1/64
(330.5)
* The removed pipe port cover can be
kept in the mounting plate pocket.
Use tape measure as shown.
Place a leveler
Position the end of a tape
on raised tab.
measure at
(Bolt size: 3/8 (M10))
9-23/32
(247)
Gas pipe end
6-19/64
Liquid pipe end
(160)
13-1/32
(331)
30-5/16
(770)
Removed pipe
port cover
A
Mounting plate
Installation Manual
.
4-31/32
(101)
2-1/8
Through-
the-wall hole
(54)
φ2-9/16 (φ65)
Drain hose
unit: inch (mm)
position
5
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents