Haier AB092XCERA Service Manual page 8

X multi series
Hide thumbs Also See for AB092XCERA:
Table of Contents

Advertisement

Item
Function
Rating capacity
Power input (indoor + outdoor)
Current input (indoor + outdoor)
EER / COP
Minimum capacity
Power input
Maximum capacity
Power input (indoor + outdoor)
Power source
Max.Running current (indoor + outdoor)
Power facor(under rating power input)
Fuse size (recommended size)
Compressor
Fan
Heat exchanger
Dimension
(WxDxH)
Refrigerant control method
Defrosting method
Crankcase heater power
Noise level
Weight
Refrigerant
Pipe
Connecting method
Between I.D &O.D
1. The above performance data are from the combination of AU252XGERA+3*AD092XLERA
2. Large drop and long piping installation will obviously reduce the total capacity.
Model / Manufacture
Oil charge and type
Type
Number
Type × Number
Speed
Motor output/input power
Air-flows (H/M/L)
Type / Diameter
Face area
External
Package
H/M/L
Net / Shipping
Type / Charge
No need to recharge
Recharge
Liquid
Gas
Max.Drop between IU &OU
Max.Drop between IU & IU
Max.Drop between IU & OU
Max.Piping length between IU & OU
Max.Total length
-8-
Model
AU252XGERA
Cooling
——
W
7250
W
2250
A
10.4
3.22
W/W
W
1500
W
500
8200
W
3200
W
1PH, 220-230V~, 50Hz
——
A / A
14.3
——
99%
A
TNB175FLBM / MELCO
——
——
DC TWIN ROTARY
——
——
——
930 / 700 / 500
r/min
W
m³/h
mm
mm
1065/420/815
mm
——
Automatic by reversible cycle
——
W
dB(A)
kg / kg
kg
m
g/m
mm
mm
——
m
10(indoor unit lower than outdoor unit)
m
15 (indoor unit higher than outdoor unit)
m
m
m
Heating
8000
2200
10.4
3.64
1800
500
9000
3000
13.5
99%
30
870CC
1
Axial × 1
98/200
about 3400
TP2M / 7.0
about 0.67
976/335/732
PMVs
35
57/-/-
58 / 64
R410A / 2.5
30
20
4* Φ6.35
4* Φ9.52
Flared
5
25
60