4.8. Console type AF***XCERA
Fig1
330
Fig2
Fig3
Tool necessary
1. Screw driver
2. Hacksaw
3. 70mm dia.hole core drill
4. Spanner(dia. 17,27mm)
5. Spanner(14,17,27mm)
6. Pipe cutter
7. Flaring tool
8. Knife
9. Nipper
10. Gas leakage detector or soap water
11. Measuring tape
12. Reamer
13. Refrigerant oil
Installation of indoor unit
selection of installation place
Place where it is easy to route drainage pipe
and outdoor piping.
Place ,away from heat source and with less
direct sunlight.
Place where cool and warm air could be
delivered evently to every corner of the room.
Place near power supply socket.Leave
enough space around the unit.
Place ,robust not causing vibration,where the
body can be supported sufficiently.
To prevent interference, place it at least 1m
away from other electric machines, such as
TV set, radio.
Installing
According to the dimension of the figure 2
shown, nail two cement steel nails on the
wall,Keep 2~3mm out.then hang the back of
the unit on them.
There must be no gap between the indoor
unit and wall.
Remove the front panel,then use two
expansible screws to fix the unit on the floor.
As figure 3 shown.
Once refrigerant piping and drain piping
connections are complete,fill the gap of the
throght hole with putty.
Attach the front panel and front grille in their
orginal positions once all connections are
complete.