  • Page 1 Install Guide 6005...
  • Page 2 Install Guide 6005 To avoid electrical shock and to prevent damage to the furnace, air conditioner, Caution and thermostat, disconnect the power supply before beginning work. This can be done at the circuit breaker, or at the appliance. You will need #1 Phillips screwdriver (small) and Tools Drill with 3/16-in.
  • Page 3: Remove Old Unit

    Loosen all screws on the old thermostat and remove it from the wall. Mount the 6005 Separate front from back of unit. Grasp the front of the unit and the back of the unit and pull apart. The thermostat body away from the base.
  • Page 4 4 Before you Connect Wires Strip insulation 3/8 in. (9.5mm) from wire ends. Connect labeled wires only to a terminal with the same letter. Bend the wire slightly, insert the wire under the contact plate and tighten the screw down onto the wire. D o n o t a l l o w w i r e s t o t o u c h e a c h o t h e r o r Caution p a r t s o n t h e r m o s t a t .
  • Page 5: Install Batteries

    Reattach the the body onto the base by pressing it firmly onto the base. Install Batteries The 6005 requires 2AA batteries if the C wire is not available in your furnace installation. Remove the control unit form the wall unit.
  • Page 6: Check Unit

    The batteries will last well over 1 year. If the batteries are not replaced the thermostat will stop working. 2) The 6005 can run on the C wire if available. As shown in the wiring diagrams. If the C wire is used, the batteries are not needed.