7193 Owner's Guide

Chapter 4: Diagnostics

The following diagnostic tests are available for the 7193:

Level 0 Diagnostics

The printer automatically performs level 0 diagnostics during the startup cycle when
power is supplied or when the printer is put on-line. Level 0 diagnostics comprise the
following actions:
When the last step is complete, the Paper Feed button is enabled and the printer is ready
for normal operation. Information about the test is available to the communication
interface through the commands.
If the printer has not been turned on before, or a new EEROM has been installed, the
default values for the printer functions (set in Level 1 Diagnostics) will be loaded into the
EEROM during level 0 diagnostics. The printer beeps twice when this occurs. See the tables
in "Level 1 Diagnostics" for the printer settings. If the printer beeps twice at any other
time, it indicates that the EEROM has failed.
Level 0 Diagnostics
Performed during the startup cycle
Level 1 Diagnostics (setup mode)
Available in a dedicated environment and accessed through the DIP Switches
Level 2 Diagnostics
Performed during normal printer operation
Level 3 Diagnostics
Maintained during normal operation and printed in the print test
Motors are turned off
Microprocessor timing is checked, CRC check of the firmware ROM is performed,
external RAM is read
Failure causes level 0 diagnostics to stop; the printer beeps once when the test is
successfully completed.
Checks if paper is present
Homes knife
Failure causes a fault condition.
Checks if receipt cover is closed
Failure does not interrupt the startup cycle.
August 1998
Chapter 4: Diagnostics
25