COOLING SYSTEM
THERMOSTAT
A !herrnostat, located near !he manifold at !he front of!he
engine, controls !he coolant temperature as !he coolant
continuously flows through !he closed cooling circuit When
!he engine is first started, !he closed !hermostat prevents
coolant from flowing (some coolant is by-passed 1hrough a
hole in !he !hermostat to prevent !he exhaust manifold from
overheating). As !he engine warms up, !he !hermostat
gradually opens. The !hermostat is accessible and can be
checked, cleaned, or replaced easily. Carry a spare !hermostat
and gasket
.
Replacing the Thermostat
Remove the cap screws and disassemble !he !hermostat
housing as shown. When instaJling !he new !hermostat and
gasket, apply a 1hin coat of sealant on bo!h sides of !he
gasket before pressing it into place. Del
not
over-tighten !he
cap screws.
Run !he engine and check for normal temperatures and !hat
there are no leaks at !he !hermostat housing.
,.
BLEED PETGDGK
FOR PUSHING AIR FROM THE
, ">COOLING SYSTEM
GASKET
tOft~7~TACKSEALANT
THERMOSTAT
ASSEMBLY
RAW WATER INTAKE STRAINER
NDTE:
Always install the strainer at or below the waterline so
the strainer will always be self-priming.
A
clean raw water intake strainer is a vital component of !he
engine's cooling system. Include a visual inspection of !his
strainer when making your periodic engine check. The water
in !he glass should be clear.
Perform !he following maintenance after every 100 hours of
operation:
1. Gose the raw water seacock. '
2. Remove and clean !he strainer filter.
3. Clean !he glass.
4.
Replace the washer if necessary.
5. Reassemble and install !he strainer.
6. Open the seacock. .
7. Run !he engine and check for leaks.
NDTE:
Also follow
the
above procedure after having run hmii
aground.
If !he engine temperature gauge ever shows a higher 1han
normal reading, !he cause may be !hat silt, leaves or grass
may have been caught up in !he strainer, slowing !he flow of
raw water through !he cooling system.
WASHER":'';~;!~V
INCOMING
TYPICAL RAW
WATE;R~~~
(OWNER INSTALLED)
INSPECT AND
CLEAN EVERY
100 HOURS