Westerbeke BCD 4.4KW Operator's Manual page 61

Marine diesel generator sets
Hide thumbs Also See for BCD 4.4KW:
Table of Contents

Advertisement

THE 17 PlUG IS
SHOWN CONNECTED
TO THE CAPACITOR
ONLY FOR DEMON-
STRATION PURPOSES.
BCD G.OKW GENERATOR
58 Hertz
Plug
A.
Check the resistance of the exciter windings
BCD 6.0KW : 2.2 Ohm
C. Check the engine's speed.
60 Hertz: 60.5 - 61.5
50 Hertz: 50.5 - 51.5
AC Load Connection
Ter.inal Block
Capacitor
CAUTION;
DO NOT
ALLOW
THESE PLues TO TOUCH
THE CENERATOR-S HOUSING.
WXNDING WILL BURN IF
PLues TOUCH HOUSING OR
OTHER WIRES.
B. Check the capacitor.
BCD 6.0KW: 31.0 uF ± 5°
Adjust the engine's speed by use of the governor/fuel solenoid linkage adjustment, page 73, to obtain the
correct Hertz.
NOTE: Refer to the "NOTE" at the bottom of page 59.
Westerbeke Generators
58

Advertisement

Table of Contents
loading

Table of Contents