Westerbeke BCD 4.4KW Operator's Manual page 59

Marine diesel generator sets
Hide thumbs Also See for BCD 4.4KW:
Table of Contents

Advertisement

SO Hertz Plug
CAUTION-
DO
NOT
ALLOW ANY
OF THESE
PLUGS
TO
TOUCH
THE
GENERATORoS HOUSING ..
WINDINGS WILL BURN
IF THESE PLues TOUCH
THE
HOUSING
OR OTHER
WIRES ..
N
+'
I..
Qj
:::c
o
LI'I
BCD 4.4KW GENERRTOR
A.
Check the resistance of the exciter windings
BCD 4.4KW : 1.9 Ohm
C. Check the engine's speed.
60 Hertz: 60.5 - 61.5
50 Hertz: 50.5 - 51.5
THE 17 PLUG IS
SHOWN CONNECTED
TO THE CRPRCITOR
ONLY FOR DEMON-
STRRTION PURPOSES.
AC Load Connection
Ter.inal Block
B. Check the capacitor.
Generator End
Plate
BCD 4.4KW: 31.0 uF
±
Adjust the engine's speed by use of the governor/fuel solenoid linkage adjustment, page 73, to obtain the
correct Hertz.
NOTE: Refer to the "NOTE" at the bottom of page 59.