*3. Retorque the cylinder head bolts.
*4. Adjust valve clearances.
5. Adjust the GovemorlFresh water pump and
Raw
Water Pump drive belt tension,
if required.
*6. Adjust the engine's no-speed, ifrequired (Hertz). Please note that these adjustments are not a
warrantable adjustment during or after the unit's break-in.
*7. Check ignition point gap and engine timing. (Check condition of distributor cap rotor.)
Servicing After Every 100 Hours of Operation
1. Change the engine's lubrication oil and oil filter.
2. Adjust the water pwnp drive belt tension, if required.
3. Check syphon break for proper operation. (when installed)
Servicing After Every 250 Hours of Operation
Clean or replace the fuel filter element in the carburetor.
Servicing After Every 500 Hours of Operation
*
1. Adjust the valve clearances.
*2. Drain, flush and refill the fresh water cooling system
*3. Check the condition of the starter motor drive pinion; lubricate pinion.
*4. Check the raw water pump for internal wear. Examine the pump's cover, cam, and internal housing.
Replace worn parts as needed. Check for leaks and repair them as needed.
5. Check the outside of the engine. Make sure that any oil on the engine's surface is cleaned. Any dirt or
oil on the engine inhibits the engine's ability to remain cool. Please keep the engine clean.
6. Check spark plug gap, ignition point gap and ignition timing.
7. Inspect plug wires, distributor cap and rotor.
8. Check water injected exhaust elbow for carbon and/or corrosion build-up on inside passages.
Clean/replace as needed.
9. Change governor lube oil.
Servicing After Every 800 Bours of Operation
*
Check the tightness of bolts, nuts, clamps.
Westerbeke Generators
64