IWARNINGI
When installing the optional remote start panel or the optional remote instrument panel, it is
the installer's responsibility to comply with U.S. Coast Guard Standards 33 CFR PART 183.
Generator AC Load Connections
CAUTION
ALL 115 VOLT LOADS MUST BE DIVIDED UP AND CONNECTED IN SUCH A MANNER THAT
CURRENT FLOWING IN ANY OF THE THREE LEGS (G1, G4, G2/G3) DOES NOT EXCEED
THE LOWEST AMPERAGE RATING ON THE GENERATOR'S DATA PLATE.
The generator
data plate gives the voltage,
amperage and hertz
rating of the generator.
The generator set wir ing decal located on
the cover of the generator mounted control panel shows the electrical
connections for 115 or 230 volt AC
output~
This
is
a
single
phase,
4 lead
wi th
vol tage
com-
binations
of
115
volt,
two
wire,
or
115/230
volt,
three
wire.
All 115 volt devices must
be connected to one of the two
115
volt sources
and
all
230
volt devices must be connected
to the 230 volt source.
For
all
115
volt
loads,
half of the generator's rated
capacity
may
be
taken
from
leads
Gl
and
G2/G3
and
half
from G4 and G2/G3.
230
Volt
loads
are
con-
nected
to
Gl
and
G4
at
full
generator rated capacity.
CAUTION:
ALL
115 VOLT
LOADS
MUST
BE
DIVIDED
UP
AND
CONNECTED
IN
SUCH
A
MANNER THAT CURRENT FLOWING
IN ANY OF THE THREE LEGS
(GI,
G4,
G2/G3)
DOES
NOT
EXCEED THE LOWEST AMPERAGE
RATING ON THE DATA PLATE.
4WIRE
1. WHEN THE ELECTRICAL SYSTEM IS A TWO WIRE TYPE
REQUIRING ONLY 120 VOLTS:
~'-----1
z
w
a:
:)
....
<t
::E
~'------I
2. WHEN THE ELECTRICAL SYSTEM IS A THREE WIRE TYPE
REQUIRING 120V. OR 120/240 VOLTS:
~'-----i
z
o
z
~
w
a:
:)
I-
<t
::E
~'------;
12-1
NEUT.
230 V