SERVICE BULLETIN
DATE:
June 21, 1985
BULLETIN NUMBER:
156
MODEL:
Westerbeke 6.5KW, 8.0KW and 11.OKW Gasoline Generators
SUBJECT:
Filling the Fresh Water Cooling System
1.
A mixture of ethylene glycol based antifreeze and fresh water
should be used in the fresh water cooling system of the 6.5KW,
8.0KW and 11.OKW gasoline generators.
A 50/50 mixture of anti-
freeze and fresh water is recommended in the fresh water cooling
circuit.
Follow the mixture directions as given by the antifreeze
manufacturer.
2.
Insure that the coolant recovery tank supplied with each generator
is installed as shown in Service Bulletin #147.
Coolant Recovery Tank
Ii
1\
.~--
........
3.
Remove the pressure cap from the manifold and open the air bleed
petcock located just forward of the thermostat housing which is
beneath the distributor.
NOTE:
On early models, a 1/8 pipe plug is used.
117