___ ANTI-SIPHON OEVICE OR ELECTRICALLY
~
OPERATED FUEL STOP VALVE
- - - - -
- - ;:;;L-;::;- T;;;
LEVEl~
/
FUEL LINE BELOW FUEL TANK TOP LEVEL
ANTI-SIPHON DEVICE OR ELECTRICALLY OPERATED FUEL STOP
VALVE AT FUEL TANK WITHORAWAL FITTIN'
FUEL TANK TOP LEVEL
ANTI-SIPHON DEVICE OR ELECTRICALLY
I
OPERATED FUEL STOP VALVE
~
FUEl LINE ABOVE FUEL TANK
TOP LEVEL
FUEL LINE BELOW FUEL TANK
TOP LEVEL
ANTI-SIPHON DEVICE OR ELECTRICALLY OPERATED FUEL
STOP VALVE AT POINT WHERE FUEL DISTRIBUTION LINE
60ES BELOW FUEL TANK TOP LEVEL
NOTE: The use of check valves instead of a solenoid shut off valve is not recommended, as
these may tax the fuel lift pump's ability to draw fuel through a check valve. Check valves can
trap dibris under their seat which inhibits the valve's ability to close. In addition, if a check
valve's cracking pressure is too high, it may cause vapor lock.
It is recommended that an approved filter/separator be used in the fuel supply between the fuel tank and the
generator's engine to help remove contaminants in the fuel before the fuel reaches the engine-mounted fuel
lift pump and carburetor.
IWARNINGI
Gasoline leakage in or around the generator compartment is a potential cause of fire and/or
explosion. Repair leaks promptly and ensure that the compartment is properly ventilated.