Air Reguirements (Minimum Values)
Model
Engine
Generator
6.5 KW
40 cu.ft./min
200 cu.ft./min
8 KW
40 cu.ft./min
220 cu.ft./min
11 KW
53 cu.ft./min
250 cu.ft./min
In confined compartments fresh cool air should be brought into the
compartment by means of AC or DC blowers and necessary ducting.
This
air should be directed at the generator end bell opening.
Unwanted
hot
air
should
be
allowed
to
exhaust
from
the
compartment.
Sizing
The proper
sized generator
to maintain the average vessel load
should be installed, otherwise compromises when loading will have to
be worked out.
An inventory of the vessel's AC loads should be made paying par-
ticular attention to motor loads that the generator will have to start
and run.
(The amperage draw of a motor when starting can be as much
as 3 - 5 times its normal running amperage.)
Determine the average AC load of the vessel and size the generator
to handle this load with reserve.
Model
Volts
Amps
6.5-614 (60 Hertz)
115/230
56/28
4.9-514 (50 Hertz)
115/230
43/21
8.0-614 (60 hertz)
115/230
70/35
6.0-514 (50 Hertz)
115/230
52/26
11.0-614 (60 Hertz)
115/230
94/47
8.5-514 (50 Hertz)
115/230
74/37
Exhaust System
All exhaust systems should be such that the entry of water into
the
engine
exhaust
manifold
and
cylinders
is
prevented
while
the
engine
is
not
running,
when
the
vessel
is
under
sailor
power,
healing, backing down,
from following seas or any other conditions.
Special attention must be made to insure that the system is secure and
tight and free of leaks.
WARNING
CARBON MONOXIDE EXHAUST GAS IS DEADLY.
6