Lay-Up And Recommissioning - Westerbeke 7.6 KW BTD 60Hz Operator's Manual

Marine diesel generator set
Table of Contents

Advertisement

LAY-UP AND RECOMMISSIONING
General
Many owners rely on their boatyards to prepare their craft, including engines and generators, for lay-up
during the off-season or for long periods of inactivity. Others prefer to accomplish lay-up preparation
themselves.
The procedures which follow will allow you to perform your own lay-up and recommissioning, or to use
as a check list if others do the procedures.
These procedures should afford your engine protection during a lay-up and also help familiarize you with
the maintenance needs of your engine.
If you have any questions regarding lay-up procedures, call your local servicing dealer; he will
be
more
than willing to provide assistance.
Fresb Water Cooling System
A 50-50 solution of antifreeze and fresh water is recommended for use in the fresh water cooling system at
all times. This solution may require a higher concentration of antifreeze, depending on the area's winter
climate. Check the solution to make sure the antifreeze protection is adequate.
Should more antifreeze be needed, drain an appropriate amount from the engine block and add a more
concentrated mixture. Operate the engine to ensure a complete circulation and mixture of the antifreeze
concentration throughout the cooling system. Now recheck the antifreeze solution's strength.
Lubrication System
With the engine warm, drain all the lubricating oil from the oil sump. Remove and replace the oil filter.
(place some paper towels and a plastic bag around the filter to catch the oil during its removaL)
When installing the new oil filter, be sure to apply a small amount of oil on the rubber sealing gasket at
the base of the filter. Fill the sump with the correct amount of oil for your engine.
(Refer to the
"SYSTEM SPECIFICATIONS" section of this manuaL) Use an oil with an API specification of CC or
CD. Run the generator and check for proper oil pressure and make sure there are no leaks.
II
CAUTION
II
Do not leave the engine's old lubricating oil in the sump over the lay-up period. Lubricating oil
and combustion deposits combine to produce harmful chemicals which can reduce the life of
your engine's internal parts.
WESTERBEKE GENERATORS
70

Advertisement

Table of Contents
loading

This manual is also suitable for:

5.7 kw btd 50 hz

Table of Contents