Description Of Instrument Panel - Westerbeke 7.6 KW BTD 60Hz Operator's Manual

Marine diesel generator set
Table of Contents

Advertisement

General
o
DESCRIPTION OF INSTRUMENT PANEL
PREHERT
4
w
START
~
WJ
STOP
®
GENERRTOR
o
o
o
The manually operated series of Westerbeke generators is equipped with toggle switches and optioual
remote panels. The Standard Instrument Panel (shown above) includes two gauges which indicate water
temperatnre in degrees Fahrenheit (WATER OF) and oil pressure in pounds per square inch (OIL PSI).
This panel is also equipped with two meters which indicate DC control circuit voltage (VOLTS) and the
generator's running time (ELAPSED TIME) in HOURS and in 1/19 hours. The water temperature and oil
pressure gauges and the DC volt meter are illuminated; the ELAPSED
TIME
meter is not illuminated.
I. PREHEAT: The PREHEAT switch energizes the engine's glow plugs, activates the electric fuel
pump, bypasses the engine's oil pressure switch, and activates the fuel run solenoid. In addition, this
switch energizes the START switch.
2. START: The START switch, when pressed, energizes the starter's solenoid which cranks the
engine. This switch will not operate electrically unless the PREHEAT switch is pressed and held at
the same time.
3. STOP: Through the STOP switch power is provided to the fuel solenoid. Opening this switch
deactivates the fuel solenoid and shuts off fuel to the engine, thereby stopping the engine.
NOTE: When the engine is manually shut down, the water temperature gauge and oil pressure
gange will continue to register the last temperature reading and oil pressure reading indicated
by the gauge before electrical power was turned off. The temperature gauge and oil pressure
gauge will return to zero once electrical power is restored to these gauges.