STOPPING PROCEDURE
1. Remove the AC electrical loaf from the generator and allow the generator to run for 3 to 5 minutes to
stabilize its operating temperature.
2. Depress the STOP switch and hold it until the generator is completely stopped.
3. Now release the STOP switch.
Remote Stopping Procedure
To stop the generator, depress the STOP switch which opens the normally closed B+ path for voltage to
the engine's run circuit. The bright green LED will go dim/faint when the generator slows and stops.
Then it will go out, indicating the engine has stopped. The STOP switch must be held open until the
generator comes to a complete stop. Remote start panels may be connected to the generator set as
indicated. A jumper has to be removed between the T -1 and T -2 connections at the panel connection
terminal board. (Refer to the wiring diagram in the "ELECTRICAL SYSTEM" section of this manual for
remote start/stop panel connections.)