Westerbeke 7.6 KW BTD 60Hz Operator's Manual page 73

Marine diesel generator set
Table of Contents

Advertisement

1.
Visual access to the fuel injection pump's fuel rack is needed. To obtain this, remove the small square
side coverlbracketry just below the fuel injection pump. This is shown as cover part #037045 and gasket
#036981 in the parts list
2. Thread the locknut #034669 onto the solenoid and then apply a small amount of Teflon sealant to the
threads on the solenoid.
3. Thread the solenoid into the boss on the engine and observe the solenoid plunger through the cover
opening. Allow the plunger to contact the fuel rack and move it fully into the injection pump. Do not
thread further so as to push the plunger into the solenoid.
4. Back the solenoid out 114 - 112 of a tum and secure it in position with the locknut
5. Properly connect the three electrical leads from the solenoid. Two of the connections plug into the
engine harness and the third grounds to the engine block at an adjacent inboard threaded boss with an
8mmbolt
6. Reassemble the coverlbracketry and test run the unit Ensure that the unit stops when the solenoid is
de-energized.
1.
FUE" SHUT OFF SOLENOID
#037100
2.
LOCKNUT
#034569
3.
SOLENOiD ?LUNGER
69