1.5 Stopping the ZyWALL

Always use Maintenance > Shutdown > Shutdown or the shutdown command before you turn
off the ZyWALL or remove the power. Not doing so can cause the firmware to become corrupt.

1.6 Rack-mounting

Use the following steps to mount the ZyWALL on an EIA standard size, 19-inch rack or in a wiring
closet with other equipment using a rack-mounting kit. Make sure the rack will safely support the
combined weight of all the equipment it contains and that the position of the ZyWALL does not
make the rack unstable or top-heavy. Take all necessary precautions to anchor the rack securely
before installing the unit.
Note: Leave 10 cm of clearance at the sides and 20 cm in the rear.
Use a #2 Phillips screwdriver to install the screws.
Note: Failure to use the proper screws may damage the unit.
Align one bracket with the holes on one side of the ZyWALL and secure it with the included bracket
1
screws (smaller than the rack-mounting screws).
Attach the other bracket in a similar fashion.
2
After attaching both mounting brackets, position the ZyWALL in the rack and up the bracket holes
3
with the rack holes. Secure the ZyWALL to the rack with the rack-mounting screws.
ZyWALL USG100-PLUS User's Guide
Chapter 1 Introduction
19