LG F14A8TDSA Series Service Manual page 25

Washing machine
Hide thumbs Also See for F14A8TDSA Series:
Table of Contents

Advertisement

Is the
Standpipe Height
than 1.0 m above the floor?
NO
When there is no water in the
pump casing, is the water level
frequency over 26.0khz ?
YES
Is the
connected correctly to
Connector
the
and the
Main PCB
Or is the
alright ?
Harness
YES
Is the resistance of the Pump Motor out
of range 152~175Ω?
Or is the Impeller operating normally?
OR
NO
Does the Pump motor start, when the spin mode
starts?
YES
If the drain hose blocked?
greater
YES
?
Pump Motor
Escape
Binding
Observe
of 1.0m maximum.
- Your washer will not be able to drain out
water adequately, if the standpipe exceeds 1.0 m.
In this case, water may flow back into the washer.
Check the
NO
Check the water level frequency again, if it is over
25.5KHz, replace the
switch.
Reconnect or repair the Connector.
NO
Or replace the Harness.
YES
NO
YES
28
Standpipe Height
requirements
and the
Air Chamber
If it is clogged, Pressure
Replace the
Pump
Replace the
Main
Clean the drain hose.
(clogged).
Tube
Motor.
PCB.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents