Problems While Scanning Bar Codes (continued)
Problem
When you release the Scan button
or handle trigger, the red beam of
light from the scanner does not turn
off.
CK30 Handheld Computer User's Manual
Chapter 6 — Troubleshooting and Maintaining the CK30
Solution
If the CK30 contains an imager:
If the CK30 is configured for continuous/edge
triggering, the red beam of light should remain
on. This is not a troubleshooting issue.
If the CK30 is configured for level triggering
(which is the default), the red beam of light
should turn off. If the red beam of light
remains on, there may be a problem with the
scanner. Press the Scan button or pull the
trigger again without scanning a bar code
label. If the red beam of light is still on,
contact your local Intermec service
representative.
If the CK30 contains a laser scanner:
If you set the Aim then Scan parameter to
Enable and the Turn off after good read
parameter to Disable/Auto-Trigger, the red
beam of light should remain on. This is not a
troubleshooting issue.
If the Aim then Scan and Turn off after good
read parameters are not configured on the
CK30, the red beam of light should turn off.
If the red beam of light remains on, there may
be a problem with the scanner. Press the Scan
button or pull the trigger again without
scanning a bar code label. If the red beam of
light is still on, contact your local Intermec
service representative.