OPM-4240 / OPM-4240R
3.25.
Factory Data Load (Picture Control Data)
Picture Control value such as User Mode, White Balance, RGB Data, DTV Data, DVD Data and VIDEO Data that are adjusted at the factory will be
-
applied. (It is different from Default Data Load)
Command Code: 0x83
-
One way Communication (Send to PDP)
-
Data: ID (1 byte)
-
e.g.) Load the factory value for MPDP ID No.1 and Read Picture Control Data
-
STX
CMD
Length
Value
0x02
0x83
0x01

IfyouneedFactorydatavalueforallMPDP,setthevalueofIDareaas"0x00"
STX
CMD
Length
Value
0x02
0x88
0x01

Pleasereferto"GetPictureControlData"
3.26.
DVI Over-Scan On/Off
User can select Over-scan when DTV resolution is detected from DVI input.
-
Command Code: 0xE4(On), 0xE5(Off)
-
One way communication (Send to PDP)
-
Data: ID (1 byte)
-
e.g.) DVI Over-scan On and Off for MPDP ID No.1
-
STX
CMD
Length
ID
Value
0x02
0xE4
0x01
0x01

IfyouwanttoexecuteDVIOver-Scan(On/Off)forallMPDP,setthevalueofIDareaas"0x00".
3.27.
Get Temperature Status (for IP Board)
Command for collecting temperature information of IP board
-
Command Code: 0x7F
-
Protocol Format - Two way communication (Send to PDP, Receive from PDP)
-
- Caution: It will not respond during Stand-by. It should be executed only during operating status.
* Send to PDP
STX
CMD
Length
ID
1 byte
1 byte
1 byte
1 byte
Data: ID(1 byte)
-
* Receive From PDP
STX
CMD
Length
Data
1 byte
1 byte
1 byte
1 byte
Data: ID(1 byte) + Temp. Data(1 byte)
-
Temp. Data: 0 (0x00): 0℃ ~ 127(0x7F): 127℃
-
128(0x80): -1℃ ~ 254(0xFE): -127℃
0xFF: Temp. Sensor Error
Check Sum
-
: Add all the values in "Data" area. Then perform "NOT" operation.
ID
ETX
0x01
0x03
ID
ETX
0x01
0x03
ETX
STX
CMD
Length
ID
ETX
0x03
0x02
0xE5
0x01
0x01
0x03
ETX
1 byte
Check Sum
ETX
1 byte
1 byte
62
3.28.
Adjust H-Align(for DTV, DVD mode)
If H align is not correct at the expanded image of 2x2 or wider with DTV/DVD input, it can be adjusted.
-
Also the adjusted data can be read with this function.
Command Code: 0xED(Set), 0xEE(Get)
-
Set command is one-way communication (Send to PDP), Get command is two-way communication (Send to PDP, Receive from PDP)
-
Caution: it does not respond at Stand-by status. It should be used at operative status.
Set Command (one-way communication)
-
* Send to PDP
STX
CMD
Length
Data
1 byte
1 byte
1 byte
n byte
Data: ID(1 byte) + Data(1 byte)
-
Index
ID
Adjust Data
Size
1 byte
1 byte
Value
Variable
Variable(1~5)
Length : The value of "Length" is "0x02".
-
Get Command (two-way communication)
-
* Send to PDP
STX
CMD
Length
ID
1 byte
1 byte
1 byte
1 byte
Data: ID(1 byte)
-
* Receive From PDP
STX
CMD
Length
Data
1 byte
1 byte
1 byte
1 byte
-Data: ID(1 byte) + Data(1 byte)
-Check Sum
: Add all the values in "Data" area and execute "Not" operation.
4.
The difference between OPM-4240 Protocol and MIS-4230 Protocol
4.1.
Revised or Deleted items
Protocol Format Change (Total Data length reduced): Refer to Page 50~51
-
Additional SHDN Control command will not be sent, when Data read command is sent.
-
Multi-Scale Data Format change (within 8 byte): Refer to Page 52 (3.3. Multi-Scale)
-
Picture Control Variable change
-
1."Color"and"Tint"in"UserMode"canbeadjustedonlyinDTV,DVDandVIDEO:Refertopage58(3.19.GraphicUserModeControl)
2. " Cr","Cb"and"Tint"adjustmentin"VideoData"aredeleted(VideoandS-Videocontrolarecombined):Refertopage59(3.22.VIDEOData
Control)
4.2.
Newly added items
Temperature measurement (for IP): Refer to Page 62 (3.27. Get Temperature Status (for IP Board))
-
Elapsed time: Refer to Page 56 (3.14. Elapsed Time)
-
APL Soft: Refer to Page 55 (3.11. APL Control)
-
DVI Over-Scan; Refer to Page 62 (3.27. Get Temperature Status (for IP Board))
-
Auto-Calibration: Refer to Page 56 (3.16. Auto-Calibration)
-
Infinitely Expandable
ETX
1 byte
ETX
1 byte
Check Sum
ETX
1 byte
1 byte
63