3.3.
Multi-Scale
Screen expansion command for MPDP
-
Command Code
-
0xDD (DVI), 0xDE (PC), 0xDF (DTV), 0xE0 (DVD), 0xE1(S-Video), 0xE2 (Video)
One way communication (Send to PDP)
-
Data: ID (1 byte) +X/Y(1 byte) + P(1 byte)
-
X: the number of horizontally installed MPDP
Y: the number of vertically installed MPDP
P: the location of expanded scale
X/Y: upper position 4bits - X (Max: 15), lower position 4bits - Y (Max: 15)
e.g.) 0x44 for 4 x 4 screens, 0xFF for 15 x 15 screens
e.g.) Screen expansion condition of 2x2 among 3x3 MPDP 3 sets. (Input-Source - DVI)
-
STX
CMD
Length
ID
X/Y
Value
0x02
0xDD
0x03
0x01
0x22
0x01
Value
0x02
0xDD
0x03
0x02
0x22
0x02
Value
0x02
0xDD
0x03
0x04
0x22
0x03
Value
0x02
0xDD
0x03
0x05
0x22
0x04
1.Select"DVI"from"SourceSelect"
2.Drag2x2bymouse
※Incaseexecute"①"→"②"or
Play"①"→"③",allMPDPsetsareturnedinto1:1screen.
-"X/Y"valueis0x22,"P"valueis"0x01"
3.4.
Information
Information display command for set (Input source and Resolution)
-
The information will be displayed on the selected PDP
-
after this command. (OSD display)
Command Code: 0x42
-
One way communication (Send to PDP)
-
Data: ID (1 byte)
-
e.g.) Set information check for MPDP ID No.1
-
STX
CMD
Length
ID
Value
0x02
0x42
0x01
0x01
1.Selectdesiredsetbyclickingtherightbuttonofthemouse.
2.SelectONEPDPandClick"INFO"ontherightside
※ I fyouneedtochecktheallMPDPsets,selectALLPDPatthestep"①"and
executestep"②"
-ExecuteBroadCastwiththe"ID"areavalueof"0x00"
ID : 1
ID : 2
ID : 3
ID : 4
ID : 5
ID : 6
P
ETX
0x03
0x03
ID : 7
ID : 8
ID : 9
0x03
0x03
ID : 1
ID : 2
ID : 3
ID : 4
ID : 5
ID : 6
ID : 7
ID : 8
ID : 9
ETX
0x03
52
3.5.
Auto-Power Mode
The command for set or cancel automatic power on when AC power is connected
-
Command Code: 0x62(Set), 0x63(Cancel)
-
One way communication (Send to PDP)
-
Data: ID (1 byte)
-
e.g.) Set or Cancel Auto Power mode for the ID No. 1 MPDP
-
STX
CMD
Length
ID
Value
0x02
0x62
0x01
0x01

IfyouneedtosetorcancelAutoPowerModeforallMPDP,setthevalueofIDareaas"0x00".
3.6.
Global Offset
Command for removing the image data of the seam area (set) for better continuous image or displaying the image data of the seam area (cancel).
-
Command Code: 0x74 (Set), 0x73 (Cancel)
-
One way communication (Send to PDP)
-
Data: ID (1 byte)
-
e.g.) Set or cancel Global Offset command for MPDP ID No.
-
STX
CMD
Length
ID
Value
0x02
0x74
0x01
0x01

IfyouneedtosetorcancelGlobalOffsetModeforallMPDP,setthevalueofIDareaas"0x00".
3.7.
Test Pattern
Command for check the set condition with the internal test pattern.
-
Command Code: 0x57 (Red), 0x58 (Green), 0x59 (Blue), 0x5A (White), 0x5B (Screen)
-
To return to main screen: 0x5B
-
One way communication (Send to PDP)
-
Data: ID (1byte)
-
e.g.) Set or cancel White Test Pattern for MPDP ID No. 1
-
STX
CMD
Length
ID
Value
0x02
0x5A
0x01
0x01

IfyouneedtosetorcancelTestPatternforallMPDP,setthevalueofIDareaas"0x00".
3.8.
Position
Command for moving screen position of Component(DTV, DVD), Composite(Video), and S-Video image input.
-
Command Code: 0x6E (Up), 0x6F (Down), 0x70 (Left), 0x71 (Right), 0x72 (Center)
-
Data: ID(1 byte)
-
e.g.) Move to the left side or cancel for MPDP ID No.1
-
STX
CMD
Length
ID
Value
0x02
0x70
0x01
0x01

IfyouwanttosetthepositionofallMPDP,setthevalueofIDareaas"0x00".
Infinitely Expandable
ETX
STX
CMD
Length
ID
ETX
0x03
0x02
0x63
0x01
0x01
0x03
ETX
STX
CMD
Length
ID
ETX
0x03
0x02
0x73
0x01
0x01
0x03
ETX
STX
CMD
Length
ID
ETX
0x03
0x02
0x5B
0x01
0x01
0x03
ETX
STX
CMD
Length
ID
0x03
0x02
0x72
0x01
0x01
53
ETX