How To Control Bic - Orion OPM-4240 User Manual

Infinitely expandable mpdp
Table of Contents

Advertisement

OPM-4240 / OPM-4240R

How to Control BiC

1.MSCS
1) MSCS and MPDP must be always connected.
2) If MSCS command is executed prior to the BIC command, the BIC command will be executed again
one hour later.
3) Turn off the energy save mode of the computer.
4) The compensation for undesirable burn-in effect is made automatically when BIC function is executed.
If the compensation result is not satisfactory, use additional Burn-in compensation function in MSCS.
(Please see page 39 for further information.)
Connect to RS-232C in MPDP
MSCS
IP
B/D
IP
B/D
※BIC board is installed inside of MPDP unit.
※ BIC function is working hourly by MSCS.
2. The other control program (beside MSCS)
Refer to BIC protocol and program guide to insert BIC control program into the MPDP control program.
MPDP
MPDP
IP
BIC
BIC
B/D
B/D
B/D
MPDP
MPDP
IP
BIC
BIC
B/D
B/D
B/D
44
Infinitely Expandable
3. MF-Controller
1) If you want to use the other MPDP control program beside MSCS and you cannot integrate BIC control
program into the MPDP control program, you can use MF-Controller.
2) The numbers of MPDP units should be set by MF-Controller.
3) The MF-Controller connected to MPDP must be always turned on.
4) During BIC function is being executed, all the commands are ignored. Even the remote controller is
not responding. If BIC command is given during the command from MF-Controller is being executed,
the BIC command will be executed one hour later.
5) Please refer to the next page for MF Controller configuration.
RS232
RS232
MSCS
MF-Controller
※BIC board is installed inside of MPDP unit.
※ BIC function is working hourly by MSCS.
45
MPDP
MPDP
IP
IP
BIC
BIC
B/D
B/D
B/D
B/D
MPDP
MPDP
IP
IP
BIC
BIC
B/D
B/D
B/D
B/D