Korenix JetNet 3706 User Manual

Industrial web managed poe plus switch

Advertisement

Quick Links

Korenix JetNet 3706/JetNet 3706f
Industrial Web Managed PoE Plus Switch

User Manual

Version1.0, Oct. 2007
www.korenix.com
JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JetNet 3706 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Korenix JetNet 3706

  • Page 1: User Manual

    Korenix JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch User Manual Version1.0, Oct. 2007 www.korenix.com JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 2 Industrial Web Managed PoE Plus Switch User Manual Copyright Notice Copyright © 2007 Korenix Technology Co., Ltd. All rights reserved. Reproduction in any form or by any means without permission is prohibited. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 3 The user is cautioned that changes and modifications made to the equipment without approval of the manufacturer could void the user's authority to operate this equipment JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 4: Table Of Contents

    Power over Ethernet ................23 Network Redundancy ................27 Traffic Prioritization................33 Monitoring and Diagnostic..............35 Device Front Panel................36 Save to Flash ..................37 Logout ....................37 Powering the Powered Device (PD) Classification Mechanism..............38 Power Forwarding Capability ..............38 Appendix Product Specifications .................40 Revision History ..................42 About Korenix..................43...
  • Page 5: Introduction

    Industrial I/O device with PoE enabled. DC24V /48V PoE System For use with a DC 24V power source system, JetNet 3706/JetNet 3706f is equipped with a dual-mode PoE powering mechanism which detects power voltage input in order to execute the most beneficial powering and disconnecting process. This feature is suitable for transportation systems or any applications without a DC 48V power source.
  • Page 6: Major Features

    IEEE802.3at for 30W power budget. To recognize the PD classification ID, JetNet 3706/JetNet 3706f is equipped with a powerful micro-processor for detection, classification, powering and disconnecting purposes. JetNet 3706/JetNet 3706f automatically powers the PD with a different PD classification ID. It can deliver a maximum of 120W output with a DC 50V power input for ID number 4.
  • Page 7: Hardware Installation

    174.8mmW x 46.5mmH x 136mmD (6.82in W x 1.81in H x 5.30in D) Mylar Layout There is one Mylar that is on the top panel of the JetNet PoE Switch. It includes 4 LEDs for JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 8 JetNet 3706f Mylar layout Port Layout JetNet 3706 includes 4-Port 10/100TX that include embedded 4-Port PoE injection function in ports #1 ~#4 and 2 additional RJ-45 for JetNet 3706 (fiber for JetNet 3706f) for uplink functionality. See the following figures. JetNet 3706...
  • Page 9: Wiring Power Inputs

    Note Suitable electric wire ranges from 12 to 24 AWG. Note If the 2 power inputs are connected, JetNet 3706/JetNet 3706f will be powered from the highest connected voltage. The unit will alarm if there is a loss of power (either PWR1 or PWR2).
  • Page 10: Wiring Fast Ethernet Ports

    JetNet 3706/JetNet 3706f and Earth Ground to avoid system damage from electrical static discharge. On the right-side of JetNet 3706/JetNet 3706f , there is one earth ground screw. Loosen the earth ground screw with a screwdriver and tighten the screw after the earth ground wire is connected.
  • Page 11: Wiring Fast Ethernet Fiber Ports

    In the IEEE 802.3af standard documents, it indicates that the PD should support mode A and B and only receive power from either mode A or mode B. The following table shows the RJ-45 pin out for the PD. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 12: Din-Rail Mounting Installation

    There are 2 DIN-Rail Clips in each unit box. Each set of DIN Rail clips include 4 screws and 2 clips. If the DIN-Rail set is missing, please contact a Korenix distributor for help. Use the screws to attach the DIN-Rail clip...
  • Page 13: Preparation For Management

    The JetNet 3706/ JetNet 3706f provides HTTP Web Interface for web management. 3.1.1 Web Interface The Korenix web management page uses JavaScript. This allows you to use a standard Web browser such as Microsoft Internet Explorer or Mozilla FireFox to configure the switch from anywhere while connected to the network.
  • Page 14 10. Once you enter the web-based management interface, you can change the JetNet 3706/ JetNet 3706f’s IP address to fit your network environment. Note 1: Internet Explorer Version 5.0 or later does not allow Java applets to open sockets by default.
  • Page 15: Feature Configuration

    4 Feature Configuration This chapter explains how to configure the JetNet 3706/JetNet 3706f software and its features. The following topics are covered in this chapter: 4.1 Basic Settings 4.2 Port Configuration 4.3 Power over Ethernet 4.4 Network Redundancy 4.5 Traffic Prioritization 4.6 Monitor and Diag...
  • Page 16 The following figure is the Web UI for System. Figure 4.1.1-1 stem Description: View a description of the system. JetNet 3706 / JetNet 3706 f Industrial anagement Ethernet Switch is the name of this product. irmware Version: Display the firmware version installed on this device.
  • Page 17 (NTP) is used to synchronize computer clocks on the internet. You can configure NTP settings here to synchronize the clocks of several switches on the network. JetNet 3706/JetNet 3706f also provide Daylight Saving function. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 18 NTP client: Select the Time Setting Source to NTP client can let device enable the NTP client.It allow JetNet 3706 / JetNet3706f get time from 2 different NTP servers. The system will send request packet to acquire current time from the NTP server.
  • Page 19 43 (GMT+04:00) Abu Dhabi, Muscat 44 (GMT+04:00) Baku, Tbilisi, Yerevan 45 (GMT+04:30) Kabul 46 (GMT+05:00) Ekaterinburg 47 (GMT+05:00) Islamabad, Karachi, Tashkent 48 (GMT+05:30) Calcutta, Chennai, Mumbai, New Delhi 49 (GMT+05:45) Kathmandu 50 (GMT+06:00) Almaty, Novosibirsk JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 20 TFTP server is ready. Then type in the IP address of the TFTP Server and configuration file name. TFTP Server IP Address: Key in the IP address of your TFTP Server here. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 21 You can use show running-config to view it in the CLI. process. The following figure is the Main UI for Backup & Restore The following figure is the WEB UI for Backup/Restore Configuration - Local File mode. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 22 4.1.6 Firmware Upgrade In this section, you can update the switch with the latest firmware. Korenix provides the latest firmware on Web site (www.korenix.com). New firmware may include new features, bug fixes or other software changes. The Web site also provides release notes for the update as well.
  • Page 23 Type in the IP address of the TFTP Server and the Firmware File Name. Then click Upgrade to start the process. After finishing the transmission of the firmware, the system will copy the firmware file and replace the firmware in the flash. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 24 CLI and Web UI, our software will not reset the IP address to the default IP. The system will maintain the IP address so that you can still connect to the switch via the network. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 25 Below is the Main screen for Reboot Below is the popup alert screen to request confirmation for the Switch Reboot. Click on Yes to reboot the switch. The popup message screen below appears when rebooting the switch. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 26: Port Configuration

    Once you have finished configuring the settings, click Apply to save the configuration. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 27: Power Over Ethernet

    Flow Control: The state of the flow control. Power over Ethernet Power over Ethernet is one of the key features of JetNet 3706/ JetNet 3706f. It is in compliances with IEEE 802.3af standards and supports 30w High power forwarding capability.
  • Page 28 The following figure shows the Web UI interface for Power over Ethernet Control. You can type a value into the Power Limit column to set the limitation of power consumption. If JetNet 3706/JetNet 3706f is set to Standard mode, it will execute IEEE 802.3af power limiting rule by PD class.
  • Page 29 JetNet 3706/JetNet 3706f delivers a useful function – PD Status Detection. This provides automatic detection of a remote device powered by JetNet 3706/JetNet 3706f. If the remote system crashes or is unstable, JetNet 3706/JetNet 3706f will perform a system reboot by turning off and on again to trigger the remote device.
  • Page 30 4.3.3 PoE Status The PoE Status page shows the operating status of each PoE Port. The information includes Detection status, current PD class, Power Consumption, and delivered Voltage and Current. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 31: Network Redundancy

    Network Redundancy It is critical for industrial applications for networks to continue working non-stop. JetNet 3706 / JetNet 3706f supports standard RSTP, Rapid Super Ring,and Legacy Super Ring Client modes. Rapid Super Ring (RSR) technology is Korenix’s 2 generation Ring redundancy technology.
  • Page 32 If JetNet 3706 / JetNet 3706f is not the root bridge, and if it has not received a hello message from the root bridge in the amount of time equal to the Max Age, then JetNet 3706 / JetNet 3706f will reconfigure itself as a root bridge.
  • Page 33 Spanning Tree Protocol learning and listening states to forwarding state. This is the amount of time JetNet 3706 / JetNet 3706f will wait before checking to see if it should be changed to a different state.
  • Page 34 The most common industrial network redundancy is to form a ring or loop. Typically, the managed switches are connected in a series and the last switch is connected back to the first one. In such a connection, you can use Korenix Super Ring and Rapid Super Ring technology. Super Ring is Korenix’s 1 generation ring redundancy technology released with JetNet 4000/4500 series.
  • Page 35 Unlike JetNet 4000/4500, there is no additional DIP switch to enable the Ring Master function in JetNet 3706/JetNet 3706f. But provides Priority parameter for the Ring Master election. Priority: The switch with the highest priority (lowest value) will be automatically selected as the Ring Master.
  • Page 36 Version 1: Version 1 is Legacy Super Ring Client mode for users who need backward compatibility with JetNet 4000/JetNet 4500. JetNet 3706 / JetNet3706f supports Client mode only. After connecting the Ring Ports to the JetNet 4000/4500 Super Ring switches, the 2 Ring Ports can pass through the hello packets sent from the ring master of the Super Ring.
  • Page 37: Traffic Prioritization

    This section allows you to configure Traffic Prioritization settings for each port in regards to setting priorities. The JetNet 3706 / JetNet 3706f QoS supports 4 physical queues, weighted fair queuing (WRR) and Strict Priority scheme, which follows 802.1p COS tag and IPv4 TOS/DiffServ information to prioritize the traffic of your industrial network.
  • Page 38 JetNet 3706 / JetNet3706f supports 4 physical queues (Lowest, Low, Middle and High), users should assign CoS value to the level of the physical queue. With the JetNet 3706 / JetNet 3706f users can easily assign the mapping table or follow suggestions from the 802.1p standard.
  • Page 39: Monitoring And Diagnostic

    Monitoring and Diagnostic JetNet 3706/JetNet 3706f provides port statistics function for you to monitor the status of switch o r create a diagnostic for you to check the problem when issues with the switch occur. The following commands are included in this section: 4.6.1 Port Statistics...
  • Page 40: Device Front Panel

    Result field. Device Front Panel Device Front Panel provides Web type LED panel which indicates status of power, PoE powering and link status of Ethernet. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 41: Save To Flash

    Your web connection will log out if you do not input a command for 30 seconds. The Logout command allows you to manually log out the web connection. Click on Yes to logout, and No to go back to the configuration page. JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 42: Powering The Powered Device (Pd)

    However, 15.4w is not enough for some applications that need more than 15.4w. For this purpose, JetNet 3706/JetNet 3706f will execute power budget control based on the PD classification. It will deliver 120W power output when JetNet 3706/JetNet 3706f is attached to DC 55V power and class 4 PD.
  • Page 43 DC 24 DC 21 0.615A (Max) 13.53w (Max) DC 32 DC 29 0.615A (Max) 18.45w (Max) DC 48 DC 45 0.615A(Max) 28.29w (Max) DC 55 DC 52 0.615A (Max) 29.52w (Max) JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 44: Product Specifications

    PD classification detection, class ID 0~3 for IEEE802.3af standard, and 30W High power deliver procedures for class ID 4. Pin assignment: V+ (RJ-45 Pin 4,5), V- (RJ-45 Pin 7,8), TX (RJ-45 Pin JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 45 IP-31 grade aluminum metal case Dimension 45.5 mm (H) x 185.3 mm (W) x 136 mm (D) without DIN Weight JetNet 3706: 0.70 kg with package / 0.65 kg without package JetNet 3706f: 0.68 kg with package/ 0.64 kg with out package Environmental...
  • Page 46: Revision History

    Revision Histo Edition Date difications V0.1 23-May --2007 The first version. V1.0 10-OCT -2007 version JetNet 3706/JetNet 3706f Industrial Web Managed PoE Plus Switch...
  • Page 47: About Korenix

    In Korenix, there is no need to comp mise. Korenix takes care of everything for you! Fusion of Outs ndings ou can end your searching here. Korenix Technology is your one-stop supply center for indu strial communications and networking products.

This manual is also suitable for:

Jetnet 3706f

Table of Contents