Henny Penny 580 Maintenance Manual page 4

Henny penny corp. fryer user manual
Table of Contents

Advertisement

Be sure capillary bulb of high limit is positioned as not
to interfere with carrier or when cleaning the cookpot
wall, or damage to capillary tube could result.
15. With excess capillary line pulled out, tighten smaller nut.
16. Replace front panel.
17. Refill with shortening.
There are two fuse holders on each model of the electric fryers.
There are no fuse holder assemblies for the gas models other
than that at the main power source.
Remove electrical power supplied to the fryer by
unplugging the unit, or turning off the wall circuit
breaker or electrical shock could result.
CONTROL PANEL FUSES 3 Phase Check from #54 to #55
and #68 to #69 on fuse assembly, or the fuse can be removed
to check for a closed circuit. If not, replace the fuse (HP#
EF02-007).

Advertisement

Table of Contents
loading

Table of Contents