SmartCombi
Error
Possible causes
No water
Tap closed
Unit is defective
Leakage of water un-
Fault in the waste water system
derneath the unit
No gas
Gas tap closed
Gas pressure too low
Cooking chamber
Unit is defective
overheated
STL triggered
Unit is defective
Motor STL triggered
Motor overheated, cooling faulty
Electronics too warm
Heat source near to the cooling air intake
Cooling air intake restricted or blocked
Ambient temperature too high
Electronics too hot
Cooling faulty, ambient temperature too high
Core temperature
Sensor broken
sensor faulty
Chamber sensor
Sensor broken
faulty
No fan
●
●
●
Danger of frost
Temperature below 0 °C (32 °F)
Battery is flat
Back-up battery is flat (service life: approx.
8 years)
Perform configuration
Necessary configuration not performed
Global Foodservice Solutions
™
6.3 Cause of errors and troubleshooting
Fan not working
Missing phase
Unit is defective
Operating manual
Remedy
Open tap
●
Contact customer service
●
Do not use unit
●
Contact customer service
●
Open gas tap
●
Check gas pressure
●
Do not use unit
●
Contact customer service
●
Contact customer service
●
Allow unit to cool down
●
Check cooling air intake
●
Contact customer service
●
Check cooling air intake
●
Set a lower cooking temperature
●
Contact customer service
●
Do not use unit
●
Check cooling air intake
●
Contact customer service
●
Use cooking program without core tem-
●
perature measurement
Contact customer service
●
Use cooking program without core tem-
●
perature measurement
Core temperature sensor as substitute
●
for chamber sensor:
- Leave core temperature sensor in the
chamber
- Do not insert the core temperature
sensor into the food
Contact customer service
●
Check electrical connection
●
Observe safety information (see
"Safety information", Page
Contact customer service
●
Observe the ambient air requirements for
●
operation
Stored data will be lost in the event of a
●
power failure
Contact customer service
●
Perform configuration
●
Contact customer service
●
Faults
Chapter
10)
75