Download Print this page

La Crosse WS-1913 Quick Setup Manual

Weather center
Hide thumbs Also See for WS-1913:

Advertisement

Available languages

Available languages

Quick Links

Model WS-1913
WEATHER CENTER
Quick Setup Guide
INITIAL SETUP:
Weather Center
Wireless transmission at
915 MHz - thermo-hygro
transmitter to weather
station
Thermo-hygro
Transmitter
Cable connection between the wind sensor and
the thermo-hygro transmitter
however that all components work properly together at their chosen mounting or
standing locations.
Note: After batteries are installed in the transmitter, install the batteries in the weather
center to receive the signal from the transmitters as soon as possible. If the weather
center is powered more than 5 hours after the transmitter is powered, the weather center
will never receive the signal successfully from the transmitters. In this case, you will need
to reinstall the batteries for all the transmitters to redo the setup procedure.
After the batteries are installed, there will be synchronization between weather center and
the transmitters. At this time, the signal reception icon will be blinking. When the signal is
successfully received by the Weather Center, the icon will be switched on. (If it is not
successful, the icon will not be shown in LCD) This allows you to see whether the last
reception was successful (icon on) or not (icon off).
Short blinking of the icon shows that a reception is in progress.
If the signal reception is not successful on the first frequency (915MHz) for 45 seconds,
the frequency is changed to 920MHz and the learning is tried another 45 seconds. If still
not successful, the reception is tried for 45 seconds on 910MHz. This will also be done for
re-synchronization.
OPTIONAL
Wireless transmission
at 915 MHz – Self-
Emptying Rain sensor
to weather station
Rain Sensor (sold separately)
Wind Sensor
1
Transmitter signal reception icon
3
Note: When putting the Weather Station into operation,
it is important to have them in close proximity (e.g. on a
table) while completing wiring and set-up of the system.
This step is important to allow testing of all components
for correct function before placing and mounting them at
their final destinations (See Positioning below).
1.
Unwind the cables of the Wind sensor. Connect
the Wind sensor to the Thermo-hygro transmitter
by plugging the connector head into the socket of
the Thermo-hygro sensor.
2.
First insert the batteries into the Thermo-hygro sensor and optional rain sensor
(purchased separately) (See How to install and replace the batteries into the
Thermo-hygro sensor and How to install and replace the batteries into the rain
sensor (optional) below).
3.
Then insert the batteries into the Weather Center (See How to install and replace
the batteries into the Weather Center below). Once the batteries are installed, all
segments of the LCD will light up. It will then display the time as 12:00, the date as
1.1.09, the weather icons, and air pressure value. "- - -" will be shown for outdoor
data.
4.
The Weather Center will start receiving data from the transmitter. The transmission
reception icon will be blinking to indicate that the station is trying to get the thermo-
hygro transmitter data. The outdoor temperature, humidity and wind data should
then be displayed on the Weather Center. If this does not happen after 135 seconds,
the batteries will need to be removed from all units. You will have to start again from
step 2.
5.
The transmitter reception icon is now blinking again to indicate that the station is
trying to get the rain sensor data. It will stop blinking once the rain sensor has been
detected. If this does not happen after 135 seconds, you will need to start again from
step 2.
6.
You may need to check the cable for correct connection and all the components for
correct function by manually turning the wind-gauge by moving the wind-vane; tilting
the rain sensor to hear the impact of the internal moving seesaw, etc. (see
Positioning below).
7.
Time and date must be manually set (See Manual Setting below).
8.
After the Weather Center has been checked for correct function with regard to the
above points and found fit, the initial set up of the weather station system is finished
and the mounting of the system components can take place. It must be ensured
HOW TO INSTALL AND REPLACE THE BATTERIES INTO THE THERMO-
HYGRO TRANSMITTER
The outdoor Thermo-hygro transmitter works with 2 x AA IEC LR6,
1.5V batteries. To install and replace the batteries, please follow the
steps below:
1.
Uninstall the rain cover of the transmitter.
2.
Remove the battery compartment cover.
3.
Insert the batteries, observing the correct polarity (see the
marking in the battery compartment).
4.
Replace the battery cover and the rain cover onto the unit.
Note: When changing batteries in any of the units, all units need to be reset by following
the setup procedures. This is because a random security code is assigned by the thermo-
hygro sensor at start-up and this code must be received and stored by the weather center
in the first several minutes of power being supplied to it.
HOW TO INSTALL AND REPLACE THE BATTERIES IN THE WEATHER
STATION
The Weather Station works with 2 x C, IEC LR14, 1.5V batteries. When the batteries need
to be replaced, the low battery symbol will appear on the LCD.
Note: When changing batteries in any of the units, all units need to be reset by following
the setup procedures. This is because a random security code is assigned by the
transmitter and rain sensor (optional) at start-up and this code must be received and
stored by the Weather Station in the first 90 seconds of power being supplied to it.
Note: The stored History record will not be kept after the battery change is done on the
weather station.
Socket for wind
sensor
2
To install or replace the batteries, please follow
the steps below:
1.
Remove the battery compartment cover.
2.
Insert the batteries observing the correct
polarity (see the marking in the battery
compartment).
3.
Replace the battery cover.
4

Advertisement

loading

Summary of Contents for La Crosse WS-1913

  • Page 1 Socket for wind Unwind the cables of the Wind sensor. Connect sensor the Wind sensor to the Thermo-hygro transmitter Model WS-1913 by plugging the connector head into the socket of the Thermo-hygro sensor. WEATHER CENTER First insert the batteries into the Thermo-hygro sensor and optional rain sensor...
  • Page 2: Function Keys

    In Mode 2, this reception WARRANTY INFORMATION icon is showing the La Crosse Technology, Ltd provides a 1-year limited warranty on this product against condition of the reception manufacturing defects in materials and workmanship. of the signal from Rain...
  • Page 3: Configuración Inicial

    PRODUCT IS NOT A TOY. KEEP OUT OF CHILDREN’S REACH. must be presented upon request as proof of purchase to La Crosse Technology, Ltd or La This warranty gives you specific legal rights. You may also have other rights specific to Crosse Technology, Ltd’s authorized service center.
  • Page 4: Teclas De Función

    Después de revisar si el centro climático funciona correctamente con respecto a los CÓMO INSTALAR Y REEMPLAZAR LAS BATERÍAS EN EL TRANSMISOR puntos anteriores y aprobarlos, se da por terminada la configuración inicial del DEL TERMÓMETRO E HIGRÓMETRO sistema del centro climático y se puede proceder con el montaje de los El transmisor del termómetro e higrómetro funciona con 2 baterías AA, componentes del sistema.
  • Page 5: Pantalla Lcd

    La Crosse Technology, Ltd, se debe presentar la factura original con fecha como prueba manera particular antes de comenzar a taladrar cualquier orificio de montaje. de la compra en La Crosse Technology, Ltd o en el centro de servicio autorizado de La Sensor de viento Crosse Technology, Ltd.
  • Page 6 LA CROSSE TECHNOLOGY, LTD NO ASUMIRÁ NINGÚN TIPO DE RESPONSABILIDAD POR DAÑOS ACCIDENTALES, RESULTANTES, PUNITORIOS O DE OTRO TIPO ASOCIADOS CON LA MANIPULACIÓN O MAL FUNCIONAMIENTO DE ESTE PRODUCTO.