Specifi cations

Electrical
Each ice machine requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 220-240/50/1
Maximum ice machine fuse – 20 amps
Amperage – 16 amps
Maximum power – 5280 watts
Climatic class – N
6 ft (2m) cord provided on ice machine
• Plug must be provided by the end-user and must conform to standard EN 60 335-2-24:2003 of the end
destination
• If the supply cord is damaged, it must be replaced by the manufacturer or their service agent, or a similarly
qualifi ed technician in order to avoid a hazard
Plumbing
3/8" OD push-in water inlet
3/4" MPT drain
1/4" FPT condenser inlet (water-cooled condenser only)
1/4" FPT condenser drain (water-cooled condenser only)
Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).
Drain to be hard piped and insulated.
To prevent back fl ow, do not connect drains.
Separate drains for ice machine and condenser.
Water shut-off recommended within 10 feet (3m).
Follett recommends installation of Follett model 00130286 activated carbon fi lter in ice machine inlet water
line.
Ambient
Air temperature
Water temperature
Water pressure – potable
Note:
Water-cooled condenser pressure 150 psi max (1034kPa); 10 psi min (69kPa)
Heat rejection
Air-cooled rejects 15,500 BTU/hr to air (3906Kcal/hr) to air
Water-cooled rejects 15,500 BTU/hr to water (3906Kcal/hr) to water
Ice production
Air-cooled ice machine capacity/24 hrs.
Ambient Air Temperature F/C
F
60
70
80
90
100
C
16
21
27
32
38
50
1367
1293
1175
1083
994
620
586
533
491
451
10
1287
1211
1119
1047
957
60
16
584
549
508
475
434
70
1219
1140
1062
999
914
21
553
517
482
453
415
1160
1078
1006
969
868
80
526
489
456
439
394
27
90
1109
1026
950
882
821
32
503
465
431
400
372
100 F/38 C max.
90 F/32 C max.
70 psi max. (483 kPa)
Water-cooled ice machine capacity/24 hrs.
Condenser Water Temperature F/C
F
60
70
80
90
C
16
21
27
32
lbs
50
1360
1313
1267
1220
kg
617
596
575
553
10
lbs
1318
1272
1225
1178
60
598
577
556
534
kg
16
1291
1244
1197
1150
lbs
70
586
564
543
522
kg
21
1249
1202
1155
1108
lbs
80
567
545
kg
27
524
503
90
1207
1160
1114
1067
lbs
32
548
526
505
484
kg
CAUTION
50 F/10 C min.
45 F/7 C min.
10 psi min. (69 kPa)
100
38
1173
lbs
532
kg
1131
lbs
513
kg
1103
lbs
501
kg
1062
lbs
482
kg
1020
lbs
463
kg
5