Download Print this page

Specifi Cations - Follett Maestro Chewblet 400 Series Installation & Service Manual

Ice machine and top kit for lancer countertop ice and beverage dispensers

Advertisement

Specifi cations

Electrical
Model number
MC400 series ice machine
Ambient specifi cations
Air temperature
Water temperature
Water pressure
Plumbing
Your new ice machine is equipped with a drain line to simplify draining the evaporator and fl oat reservoir. The
tube labeled "fl oat/evap drain" is for SERVICE USE ONLY and must NOT be connected to the ice machine drain.
Water line sizes
Drain line sizes
Slope to drain
Water shut-off recommended within 10 feet (3m), drain to be hard-piped and insulated
Separate drains for ice machine and condenser. To prevent back fl ow, do NOT connect drains.
Follett recommends installation of a Follett water fi lter system (part# 00130229) in ice machine inlet water line
Field Wiring: countertop and wall mount dispensers with RIDE™ remote
ice delivery model ice machines
Consult enclosed D400A/W, R400A/W, MCD400A/W manual.
115/60/1
100 F/38 C max.
90 F/32 C max.
70 P.S.I. max. (482kPA) 10 P.S.I min. (89kPA)
Make up water (inlet to fl oat)
Condenser (water-cooled only)
Ice machine drain
Condenser (water-cooled only)
1/4" per foot (6mm per 30.4cm run)
4
Full load amps
11.0 amps
50 F/10 C min. (best performance below 80 F/27 C)
40 F/4 C min. (best performance below 70 F/21 C)
1/4" min.
3/8" min.
3/4" min.
1/2" min.
1/2" min.
Max. fuse size
20 amps

Advertisement

loading