Specifi cations
Electrical
Model number
MC400 series ice machine
Ambient specifi cations
Air temperature
Water temperature
Water pressure
Plumbing
Your new ice machine is equipped with a drain line to simplify draining the evaporator and fl oat reservoir. The tube
labeled "fl oat/evap drain" is for SERVICE USE ONLY and must NOT be connected to the ice machine drain.
Water line sizes
Drain line sizes
Slope to drain
•
Water shut-off recommended within 10 feet (3m), drain to be hard-piped and insulated
•
Separate drains for ice machine and condenser. To prevent back fl ow, do NOT connect drains.
•
Follett recommends a Follett water fi lter system be installed in the ice machine inlet water line (standard
capacity #00130299, high capacity #00978957, carbonless high capacity #01050442).
Field Wiring: countertop dispensers with RIDE
ice machines
Consult enclosed D400A/W, R400A/W, MCD400A/W manual.
4
Maestro 400 Series Top Kit for Remcor/Cornelius
Full load amps
115/60/1
+100 F/+38 C max.
+50 F/+10 C min. (best performance below +80 F/+27 C)
+90 F/+32 C max.
+40 F/+4 C min. (best performance below +70 F/+21 C)
70 P.S.I. max.(482kPA) 10 P.S.I min. (89kPA)
Make up water (inlet to fl oat)
Condenser (water-cooled only)
Ice machine drain
Condenser (water-cooled only)
1/4" per foot (6mm per 30.4cm run)
Max. fuse size
11.0 amps
1/4" min.
3/8" min.
3/4" min.
3/8" min.
1/2" min.
®
remote ice delivery model
20 amps