Specifi Cations - Follett Maestro Chewblet MSC44SC Installation, Operation And Service Manual

Ice machine and top kit for remcor/cornelius countertop ice and beverage dispensers
Table of Contents

Advertisement

Specifi cations

Electrical
Model number
MC400 series ice machine
Ambient specifi cations
Air temperature
Water temperature
Water pressure
Plumbing
Your new ice machine is equipped with a drain line to simplify draining the evaporator and fl oat reservoir. The tube
labeled "fl oat/evap drain" is for SERVICE USE ONLY and must NOT be connected to the ice machine drain.
Water line sizes
Drain line sizes
Slope to drain
Water shut-off recommended within 10 feet (3m), drain to be hard-piped and insulated
Separate drains for ice machine and condenser. To prevent back fl ow, do NOT connect drains.
Follett recommends a Follett water fi lter system be installed in the ice machine inlet water line (standard
capacity #00130299, high capacity #00978957, carbonless high capacity #01050442).
Field Wiring: countertop dispensers with RIDE
ice machines
Consult enclosed D400A/W, R400A/W, MCD400A/W manual.
4
Maestro 400 Series Top Kit for Remcor/Cornelius
Full load amps
115/60/1
+100 F/+38 C max.
+50 F/+10 C min. (best performance below +80 F/+27 C)
+90 F/+32 C max.
+40 F/+4 C min. (best performance below +70 F/+21 C)
70 P.S.I. max.(482kPA) 10 P.S.I min. (89kPA)
Make up water (inlet to fl oat)
Condenser (water-cooled only)
Ice machine drain
Condenser (water-cooled only)
1/4" per foot (6mm per 30.4cm run)
Max. fuse size
11.0 amps
1/4" min.
3/8" min.
3/4" min.
3/8" min.
1/2" min.
®
remote ice delivery model
20 amps