Specifi cations

Electrical
Each icemaker requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 220-240/50/1
Maximum icemaker fuse – 20 amps
Amperage – 16 amps
Maximum power – 5280 watts
Climatic class – N
6 ft (2m) cord provided on icemaker
• Plug must be provided by the end-user and must conform to standard EN 60 335-2-24:2003 of the end
destination
• If the supply cord is damaged, it must be replaced by the manufacturer or their service agent, or a similarly
qualifi ed technician in order to avoid a hazard
Plumbing
3/8" OD push-in water inlet
3/4" MPT drain
1/4" FPT condenser inlet (water-cooled condenser only)
1/4" FPT condenser drain (water-cooled condenser only)
Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).
Drain to be hard piped and insulated.
To prevent back fl ow, do not connect drains.
Separate drains for icemaker and condenser.
Water shut-off recommended within 10 feet (3m).
Follett recommends installation of Follett model 00130286 activated carbon fi lter
in icemaker inlet water line.
Ambient
Air temperature
Water temperature
Water pressure – potable
Note:
Water-cooled condenser pressure 150 psi max (1034kPa); 10 psi min (69kPa)
Heat rejection
Air-cooled rejects 15,500 BTU/hr to air (3906Kcal/hr) to air
Water-cooled rejects 15,500 BTU/hr to water (3906Kcal/hr) to water
Ice production
Air-cooled icemaker capacity/24 hrs.
Ambient Air Temperature F/C
F
60
70
80
90
100
C
16
21
27
32
38
1362
1290
1192
1105
989
50
618
586
541
502
449
10
60
1290
1206
1120
1033
917
16
586
548
509
469
416
70
1219
1136
1050
969
847
553
516
477
440
385
21
1148
1065
919
891
776
80
27
521
484
417
405
352
90
1077
993
907
820
714
32
489
451
412
372
324
100˚F/38˚C max.
90˚F/32˚C max.
70 psi max. (483 kPa)
Water-cooled icemaker capacity/24 hrs.
Ambient Air Temperature F/C
F
50
60
70
80
10
16
21
27
C
1128
1128
1128
1128
lbs
50
512
512
kg
10
512
512
60
1081
1081
1081
1081
lbs
16
491
491
491
491
kg
1035
1035
1035
1035
lbs
70
470
470
470
470
kg
21
lbs
80
989
989
989
989
27
449
449
449
449
kg
90
943
943
943
943
lbs
428
428
428
428
kg
32
CAUTION
50˚F/10˚C min.
45˚F/7˚C min.
10 psi min. (69 kPa)
90
32
1128
lbs
512
kg
1081
lbs
491
kg
1035
lbs
470
kg
989
lbs
449
kg
943
lbs
428
kg
5