9. TROUBLE SHOOTING
4.
a) Assuming that the indicator light blinked yellow
in test a) above. Reset all connections to their
original positions. Then disconnect A2. Connect
a new loop wire to A2.Connect the other end of
this new loop wire somewhere at the centre of
the installation.
If the indicator light is green or flashing yellow,
then the break is somewhere in the wire between
the disconnected end and the point where the
new wire is connected (thick black line in the
illustration below).
In that case, move the connection for the new
wire closer to the disconnected end (roughly at
the middle of the suspect wire section) and check
again if the indicator light is green or flashes
yellow.
Continue until only a very short section of the
wire remains which is the difference between a
flashing blue light and a solid green light.
b) If the indicator light flashed yellow in test 3b)
above, a similar test is carried out but with the
new loop wire connected to A1 instead.