11 11

Finishing

A. Mantel Projections
Figure 11.1 shows the minimum vertical and corresponding
maximum horizontal dimensions of appliance mantels or
other combustible projections above the top front edge of
the appliance.
7
6
11-1/2
5
10-3/4
4
10
3
9-1/4
8-1/2
6-1/2
Figure 11.1 Clearances to Mantels or other Combustibles above
Appliance.
Top of
Appliance
1 in. (25mm) min.
A
to perpendicular wall
B
3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall
Figure 11.2 Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
24
30 in. minimum
17
16
15
18-1/4
14
17-1/2
13
16-3/4
12
16
11
15-1/4
10
14-1/2
9
13-3/4
8
13
12-1/4
Measured from top of hood (in inches)
Drywall
A
48 in.
(1219 mm)
max.
B
Mantel Leg or
Perpendicular Wall
Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07
B. Facing Material
to ceiling
18
19
These surfaces
may be
covered with
noncombustible
material
Figure 11.3 Noncombustible Facing Diagram
Black metal appliance front may be covered with non-
combustible material only.
Do NOT overlap combustible materials onto appliance
front.
Install combustible materials only up to specifi ed
clearances on top, front and sides.
Seal joints between the fi nished wall and appliance
top and sides using only a 300° F minimum sealant.
WARNING
Fire Risk
Do NOT obstruct air inlets.
Finishing materials must not interfere with:
Air fl ow through inlets.
Access for service.
High temperature sealant
WARNING
Fire Risk
Finish all edges and fronts to clearances and
specifi cations listed in manual.
These surfaces may
be covered with
noncombustible
material