Intellifi Re Ignition System Wiring - Heatilator RBV4236IH Owner's Manual

B-vent gas appliance
Hide thumbs Also See for RBV4236IH:
Table of Contents

Advertisement

C. Intellifi re Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in Fig-
ure 10.2.
This appliance is equipped with an Intellifi re control valve
which operates on a 3 volt system.
This appliance is supplied with a battery pack and a 3 volt
AC transformer, which requires the installation of the sup-
plied junction box. It is highly recommended that the junction
box be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not included).
Batteries cannot be placed in the battery pack while using
the 3 volt AC transformer. Conversely, the transformer must
be unplugged if the battery pack is used.
CAUTION
Battery polarity must be correct or module damage will
occur.
Wall Switch
GRN*
WHT
* GRN wire only used with
optional wall switch
WSK-MLT-HTL
Figure 10.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram
22
Battery
Pack
- +
Junction
-
+
Limit
Switch
3V
Adaptor
BLK
BLK
BLU
RED
RED
Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07
Optional Accessories Requirements
Wiring for optional accessories should be done now to
avoid reconstruction.
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Ignitor
Control
Box
To
ORG
Box
BLK
BRN
ORG
GRN
Valve
CAUTION
CAUTION
Shock Risk
Replace damaged wire with type 105° C
rated wire.
Wire must have high temperature
insulation.
Flame
Sensor
Pilot Assembly
WHT
14-2 with
Ground Romex
WHITE
BLACK
GROUND

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rbv4236itRbv4842itRbv4842ih

Table of Contents