Clearances - Heatilator RBV4236IH Owner's Manual

B-vent gas appliance
Hide thumbs Also See for RBV4236IH:
Table of Contents

Advertisement

C. Clearances
Note: If the inside of the framed cavity is to be
fi nished, the framing dimensions must include
the fi nished surface. If drywall is to be attached
to the rear wall, the depth must be measured from
the drywall surface.
1/2 in.
(13 mm)
Combustible flooring may be installed
next to the front of the appliance.
30 in.
(762 mm)
to ceiling
36 in.
(914 mm)
Figure 3.2
Clearances to Combustibles
10
1/2 in.
(13 mm)
Drywall
0 in.
0 in.to level
of standoffs
0 in.
Rough Opening
(Width)
Model #
RBV4236
in.
mm
1067
RBV4842
in.
mm
1219
Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07
Fire Risk
Odor Risk
B
A
A
B
Rough Opening
(Height)
42
39-3/4
1010
48
39-3/4
1010
WARNING
Install appliance on hard metal or wood
surfaces extending full width and depth
of appliance.
Do NOT install appliance directly on
carpeting, vinyl, tile or any combustible
material other than wood.
Do NOT place furniture or any other
combustible household objects within
36 in. of the appliance front.
Per Vent Manufacturer's
Specifications
C
C
Rough Opening
(Depth)
22
559
22
559