D. Junction Box Installation
•
Remove the junction box assembly from the valve
compartment.
•
If the box is being wired from the OUTSIDE of the
appliance;
-
Loosen two screws on the Romex connector, feed the
necessary length of wire through the connector and
tighten the screws.
-
Make all necessary wire connections to the receptacle
and assemble the receptacle and cover to the junction
box.
-
Attach the junction box assembly to the outside of the
appliance with the two screws provided.
•
If the box is being wired from the INSIDE of the
appliance;
-
Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
-
Loosen the two screws on the Romex connector, feed
the necessary length of wire through the connector and
tighten the screws.
-
Make all necessary wire connections to the receptacle
and assemble the receptacle and cover to the junction
box.
-
Attach the junction box assembly to the inside of the
appliance with the two screws provided.
•
If the box is not to be wired at the time of appliance
installation, assemble the receptacle and cover to the box
and install on the inside of the appliance.
Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07
WARNING
Shock Risk
Explosion Risk
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch
•
Incorrect wiring will damage millivolt
values.
•
Incorrect wiring will override IPI safety
lockout and may cause explosion.
23