4. Existing Masonry Chimney

Type A
Co-Axial to
Co-Linear Connector
Pipe Length
(Optional)
Type C - Up & Out Installation
Top Adaptor
Retro Connector
90° Elbow
Direct Vent
Pipe
*NOTE: In the Commonwealth of Massachusettes, the word damper shall be replaced with the words flue restrictor.
Figure 5.24
Page 20
Chimney Liner
Termination Cap
3 in. (76mm)
Flex Liner
Showing (2)
30 ft. (9m)
Sections of
Flex Liner
Type A & B Co-Axial to Co-Linear
Termination Cap
Flashing
4 in. (102mm)
Flex Liner
Quadra-Fire · Castile Gas Stove · 7023-111E
Type B
Co-Axial to
Co-Linear
Connector
Pipe Length
Optional
Type D - Hearth Mount
Alcove Clearance to
Combustibles must be
maintained.
Co-Axial to Co-Linear Connector
Chimney Liner
Termination Cap
30 ft. (9m) of 3 in.
(76mm) Flex Liner
Exhaust Section
(Cut to length)
This section of the
chimney must be
sealed
The chimney must be sealed
from the 4 ft. (1m) section to
termination using a smoke
shelf or a damper*.
The seal should be 6 in.
(152mm) below the end of
the 4 ft. (1m) Air Intake
section.
4 ft. (1m) of 3 in. (76mm) Flex
Liner Air Intake Section
Chimney Liner
Termination Cap
30 ft. (9m) of 3 in. (76mm)
Flex Liner Exhaust Section
(Cut to length)
This section of the
chimney must be sealed
Chimney must be sealed
from 4 ft. (1m) section to
termination using a smoke
shelf or a damper*.
Seal should be 6 in.
(152mm) below end of 4 ft.
(1m) Air Intake section.
4 ft. (1m) of 3 in. (76mm) Flex
Liner Air Intake Section
September 1, 2008