Reliability and Life

Parameter
Mean Time Between Failures
Time to 50% brightness decay from initial brightness

Safety and Regulatory Certifications

A.
FCC Certification
FCC Part 15, Subpart B, Class B - Conducted and Radiated Tests
B.
CE Certification
Emission
EN 55022:1998+A1:2000+A2:2003; Class B
EN61000-3-2:2000, Class D
EN61000-3-3:1995+A1:2001
Immunity (EN 55024:1998+A1:2001)
IEC 61000-4-2: 2001
IEC 61000-4-3: 2002
IEC 61000-4-4: 1995+A1:200+A2:2001
IEC 61000-4-5: 2001
IEC 61000-4-6: 2001
IEC 61000-4-8: 2001
IEC 61000-4-11: 2001
C. UL/CUL Certification
TUV Certification
Specification
20k hours at 25°C, 90% confidence level
40k hours minimum at 25°C, operating
continuously at maximum brightness
Conducted & Radiated Test
Harmonic Current Emissions
Voltage Fluctuations and Flicker
Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field
immunity test
Electrical fast transient/ burst immunity test
Surge immunity test
Immunity to conducted disturbances, induced by
radio-frequency fields
Power frequency magnetic field immunity test
Voltage dips, short interruptions and voltage variations
immunity tests