Operational Specifications; Environmental; Reliability; Emc - Planar EL640.400-C2 User Manual

640 x 400 pixel displays
Table of Contents

Advertisement

Operational Specifications

Environmental

Reliability

EMC

Safety

16
EL640.400-C2, -C3 and –CD3 Operations Manual (020-0355-00A)
For ordering information of el640-400-c3 and other EL Displays, please visit http://www.eldisplays.com/el640-400-c3/ or call +1-888-394-4998.

Table 10. Environmental Characteristics.

Temperature
Operating
C2
C3
Non-operating
Operating Survival
C2
C3
Test duration 24 h
C2
at +65°C (without
C3
condensation)
Humidity
Relative Humidity
Damp Heat
Altitude
Operating
Vibration
Shock
Magnitude
Duration
Number of shocks
MTBF > 50,000 h @ 25°C
The display will not inhibit the end product from obtaining any of the
following specifications: EN55022 Class B, FCC Part 15J Class B
The display will not inhibit the end product from obtaining any of the
following specifications: UL544, IEC 950
0...+55°C
–25...+65°C
–40...+85°C
–20...+65°C (no permanent damage)
–40...+65°C (no permanent damage)
24 h at –20°C
24 h at –50°C
+40°C, 93% RH, Operating (IEC 68-2-3)
+25...+55°C, 95% RH, Non operating (IEC 68-2-30)
15,000 m (50,000 ft.) above sea level
20...500 Hz
2
ASD level 0.05 g
/Hz
Random vibration wide band
IEC 68–2–36, Test Fdb
100 g
4 ms (half sine wave)
18 (3 on each of the 6 surfaces)
IEC 68-2-27, test Ea