Specifications
Performance characteristics are guaranteed with the display at room temperature (25 °C)
and with the operating voltage within specifications, unless otherwise specified. Optical
performance is referenced to screen center at normal incidence with a full white screen
display and the backlight at maximum luminance, 60Hz LCD frame rate, unless
otherwise specified.
Environmental Characteristics
Table 2. Environmental Characteristics.
Temperature
Operating
Operating survival
Storage
Humidity
Operating
Non-operating
Altitude
Operating
Non-operating
Vibration (random)
Operating/Non-operating
Shock
Operating/Non-operating
Safety and EMI Certifications
The display will not inhibit the end product from compliance with UL1950, CSA22.2,
and IEC950. When housed in a suitable enclosure, the display will not inhibit the end
product from complying with FCC Part 15, Subpart J Class B, EN55022 Class B, or
SAE-J-1113.
Reliability and Backlight Life
The demonstrated system MTBF is to be greater than 30,000 hours with a 90%
confidence level at 25 °C. Refer to Table 3 for backlight life.
Table 3. Backlight Life.
Usage
Continuous at full luminance
Continuous at half luminance
Typical use using CBM*
* Controlled luminance mode
4
LC640.480.21-065 Operations Manual (OM610-00)
-20 to +71 °C (-40 to +71°C with cell heater/version -01)
-40 to +85 °C, 2 hrs. maximum
-45 to +90 °C, 24 hrs. maximum
93% RH @ 40 °C, non-condensing, 10 days per IEC 68-2-3
0 to 95% RH @ 25-55 ºC, 6 days per IEC 68-2-30
0 to 10k ft. per IEC 68-2-13
0 to 40k ft. per IEC 68-2-13
2
0.02 g
/Hz, 5-500 Hz, 30 min. ea. axis, per IEC 68-2-34
Specific profiles for each axis, SAE J1455, section 4.9
100 g, 6 ms, half sine wave, 3 shocks per surface, per IEC 68-2-27
Backlight life (typical to 50% of initial luminance)
20K hours
60K hours
50K hours @ 700 cd/m
2