Gas-fired direct vent heater

Advertisement

HearthStone Quality Home Heating Products Inc
NOT INSTALL the heater. Contact your
dealer for the correct model or conversion
kit.
G
P
A
AS
RESSURE
NOTE: A QUALIFIED TECHNICIAN
MUST PERFORM THIS PROCEDURE!
The supply line pressure is tested to ensure
is meets minimum pressure requirements, as
listed in the Specifications sections of this
manual, for the type of fuel in use (NG or
LP).
The unit must be isolated from the gas
supply
piping
system
individual manual shutoff valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less than
½ psig.
During tests in excess of ½ psig (14" w.c.),
the heater must be disconnected from the
gas supply system. Test by connecting a
manometer to the supply line. Adjust the
incoming pressure, if necessary, to meet the
required supply line pressure.
Once connected to the gas supply, the gas
inlet pressure and manifold gas pressure
must be tested. The gas inlet tap (6) and
manifold pressure tap (7) is located on the
control valve (see Figure 14). Connect a
manometer to the test points on the gas
control valve.
NOTE: For installations from 610-1370
meters
(2000-4500ft),
(DMS) for natural and propane gas are 32
and 49 respectively.
equipé pour des altitudes compries entre
2000 et 4500 pieds (610-1370m) seulement.)
See data plate for additional information.
For high altitude installations consult the
local gas distributor or the authority having
DJUSTMENT
by
closing
its
the
orifice
sizes
(Cet appareil est
jurisdiction for proper rating methods. If the
unit must be adjusted, the information
sticker (provided with the high altitude kit)
must be filled out completely and mounted
to the unit per the instructions provided with
the kit.
CAUTION: Fragile! Handle log set with
care. Always wear gloves and safety goggles
while handling the log set.
L
P
OG
LACEMENT
Only the decorative ceramic fiber log set
supplied with the unit should be placed in
the firebox. Do not place any other ceramic
logs, wood logs, or other materials in the
firebox. If the log set is damaged or broken
contact your dealer for replacement.
decorative ceramic fiber log set will last a
long time, however, they will break if
subjected to rough or improper handling.
Exact positioning of the log set is required in
order to obtain a pleasing flame pattern and
efficient
combustion.
placement
may
excess thermal stress on the log set and
stove parts, reduced efficiency, and high
levels of carbon monoxide. If the log set
does not set into the firebox exactly as
outlined, contact your dealer for assistance.
I
NSTALLATION OF THE
(Refer to figures 15 & 16 for log set
assembly)
1. Remove the front façade. (Refer to
page 12 for instructions)
2. Remove
around the log set assembly. Be
careful not to damage the log set
when unpacking.
3. Gently place the Rear Log (1) in the
firebox against the center of the back
wall.
28
Champlain
Model #8300
Incorrect
cause
carbon
build-up;
L
S
OG
ET
the
packaging
material
The
log

Advertisement

loading