Analog input setup

The Analog Input window (
is used to configure devices on the four analog inputs. Each tab 
corresponds to a pin:
Analog Tab
Connector Pin
Input 1
Input 2
Input 3
Input 4
To configure an analog sensor or gauge, select the tab that 
corresponds to the pin you are using and complete the fields as 
follows:
Label: Enter a description of the sensor or gauge (
Voltage
Vehicle Speed
Raw value: Shows the analog value from the input (read‐
only). The analog input has a 10‐bit (1024‐step) resolution, 
so the raw value range is between 0 and 1023.
Zero scale: Enter the minimum value for the units you are 
reporting (used to convert the raw analog value of zero).
Full scale: Enter the maximum value for the units you are 
reporting (used to convert the raw value of 1023).
Current value: Shows the resulting converted value using 
the zero and full scales entered.
Unit: Specify the units of the input (
20 characters long.
Example
If you are measuring temperature, and the thermometer you 
have connected to the I/O connector measures between ‐30 
(raw value 0) and +50 (raw value 1023) degrees Celsius, then 
-30.0
your zero scale is 
 and your full scale is 
"Temperature
could be 
", and units, 
The measurements are calculated for the 81‐degree range 
(between ‐30 and +50), which is divided into 1024 steps 
(0.0791 degrees per unit step). A reading of 25 degrees 
(56 degrees above the minimum) would therefore show a raw 
value of 708 (56 degrees/0.0791 degrees per unit).
Tools > Options > MP > Input/Output
14
7
15
8
, etc.), up to 20 characters long.
volts
km/h
50.0
. Your label 
"degrees C"
.
Measured
, etc.), up to 
2130795