Digital I/O Setup - Sierra Wireless AirLink MP595 User Manual

User guide for verizon
Hide thumbs Also See for AirLink MP595:
Table of Contents

Advertisement

Data
Rev 1.5 Jul.08
Configuring the MP Modem to Report GPS and I/O

Digital I/O setup

The Digital Input/Output window (
Input/Output > Digital I/O
) is used to configure devices on the two 
digital I/O and two digital input ports. Each tab corresponds to 
a pin:
Digital Tab
Connector Pin
I/O 1
Input or output on pin 3
I/O 2
Input or output on pin 11
Input 3
Input on pin 4
Input 4
Input on pin 12
To configure a digital sensor or gauge, select the tab that corre‐
sponds to the pin you are using and complete the fields as 
follows:
Label: Provide a description of the sensor or gauge, up to 
20 characters in length.
Input
Output
Type: Select 
available on tabs 3 and 4.)
Logic low name: Describe the state of the device at logic 
level low, up to 20 characters in length. (For example, if a 
switch in the off position leads to a logic low, you could 
Switched Off
choose to label it 
Logic high name: Describe the state of the device at logic 
level high, up to 20 characters in length (such as 
On
).
Alarm logic level: Assign an action associated with the I/O 
port:
·
high: A notification is sent, and the event is logged, if the 
state changes from a logic low to a logic high.
·
low: A notification is sent, and the event is logged, if the 
state changes from a logic high to a logic low.
·
log only: No notification is sent, but any change in logic 
level is logged.
The name and location of the log file is specified in the 
Input/Output window (
By default, the log file is located in the program folder or 
user folder and is called MpIoLog.txt. 
Current value: Shows the current value of the port.
Tools > Options > MP >
Not used
Output
, or 
. (
 is not 
.)
Tools > Options > MP > Input/Output
Switched
). 
59