Analog Input Setup - Sierra Wireless MP 595 User Manual

Sierra wireless modem user guide mp 595
Hide thumbs Also See for MP 595:
Table of Contents

Advertisement

MP 595 Modem User Guide
48

Analog input setup

The Analog Input window (
is used to configure devices on the four analog inputs. Each tab
corresponds to a pin:
Analog Tab
Connector Pin
Input 1
Input 2
Input 3
Input 4
To configure an analog sensor or gauge, select the tab that
corresponds to the pin you are using and complete the fields as
follows:
Label: Enter a description of the sensor or gauge (
Voltage
Vehicle Speed
,
Raw value: Shows the analog value from the input (read ­
only). The analog input has a 10-bit (1024-step) resolution,
so the raw value range is between 0 and 1023.
Zero scale: Enter the minimum value for the units you are
reporting (used to convert the raw analog value of zero).
Full scale: Enter the maximum value for the units you are
reporting (used to convert the raw value of 1023).
Current value: Shows the resulting converted value using
the zero and full scales entered.
Unit: Specify the units of the input (
20 characters long.
Example
If you are measuring temperature, and the thermometer you
have connected to the I/O connector measures between -30
(raw value 0) and +50 (raw value 1023) degrees Celsius, then
-30.0
your zero scale is
and your full scale is
"Temperature
could be
", and units,
The measurements are calculated for the 80-degree range
(between -30 and +50), which is divided into 1024 steps
(0.0781 degrees per unit step). A reading of 25 degrees
(55 degrees above the minimum) would therefore show a raw
value of 704 (55 degrees/0.0781 degrees per unit).
Tools > Options > MP > Input/Output
14
7
15
8
, etc.), up to 20 characters long.
volts
km/h
,
50.0
. Your label
"degrees C"
.
)
Measured
, etc.), up to
2130795

Advertisement

Table of Contents
loading