Download Print this page

Fader Cleaning - Rane MP 2S Operator's Manual

Club mixer

Advertisement

Fader Cleaning

With heavy use in harsh environments, the faders may need
lubrication. This treatment extends longevity and can make used
faders as good as new. The fader assembly must be removed from
the MP 2S for proper cleaning. We recommend any of the fol-
lowing cleaning solutions:
Caig DeoxIT FaderLube F100 spray lubricant (www.caig.com)
Caig DeoxIT FaderLube F5 spray cleaner (www.caig.com)
CRC 2-26 (www.crcindustries.com)
Order DeoxIT® from:
CAIG Laboratories, Inc.
12200 Thatcher Ct.
Poway, CA 92064
Phone 858-486-8388
Fax 858-486-8398
Web www.caig.com
©Rane Corporation 080 7th Ave. W., Mukilteo WA 9875-5098 TEL 5-55-6000 FAX 5-7-7757 WEB www.rane.com
Manual-
CLEANING INSTRUCTIONS
A. Fader assembly replacement (part #11646)
1. Unplug the MP 2S.
2. Remove the bottom cover.
3. Remove the fader screws from the front panel.
4. Draw fader assembly out through the bottom.
5. Remove ribbon cable from old fader.
6. Attach ribbon cable to new fader, screw onto front panel and
replace bottom cover.
B. Fader cleaning
1. Hold the fader assembly away from the mixer.
2. Position the fader at mid-travel.
3. Spray cleaner/lubricant into both ends of the fader in sufficient
amounts to flush debris.
4. Move the fader over its full travel back and forth a few times.
5. Shake excess fluid from the fader assembly.
6. Wipe off excess fluid.

Advertisement