QUICK START

If you have used just about any DJ mixer on the planet, you will instantly feel at home using the MP 44. Extra care was taken to
ensure that controls are where you expect them to be, and operate as you expect them to.
The MP 44 has some unique features not found on other DJ mixers. It is important that you read at least this portion of the
manual so that you get the maximum benefit from these unique features. As you refer through the rest of this manual (as you should
to get the most of it), front panel controls are on the left side of each page, rear panels are on the right.
Club Managers Section
High performance Master Limiter affects both House and Booth sig-
nals. This control is located on the rear panel and screw driver adjust
to prevent tampering. The Limiter is a safety net designed to protect
ears and equipment.
Automatic HOUSE PAGE INPUT provides a means to automatically
interrupting all program material and broadcast emergency mes-
sages at a pre set level. The HOUSE PAGE GAIN is set independent
of HOUSE- and BOOTH LEVEL control settings. The HOUSE
PAGE GAIN control is a recessed, screw driver adjusted control
located on the rear panel to prevent tampering after installation. See
page Manual-6 for more details.
REMOTE LEVEL Control Port provides a means to control the level
of the Master mix from a remote location. The range of control is
0 dB to –40 dB. Applications include "gain riding" DJs, setting a
comfortable listening level from a remote location and reducing
the maximum available gain. To use the optional VR 1 Remote
Control, simply connect like labeled pins together. Shielded wire is
recommended. See page Manual-7 for more details.
WARNING: Do not operate this unit without the line cord earth ground connected. To do so may increase the risk of elec-
tric shock and increase line cord conducted emissions.
WEAR PART
This product contains the following wear part subject to the ninety (90) day warranty period described on page Warranty-1: (1)
Active Crossover Assembly.
OPERATORS MANUAL
CH 1
CH 2
0
6
OL
OL
8
10
OFF
+6
-12
+12
OFF
+6
HIGH
LEVEL
HIGH
1A
1B
SOURCE
+8
OFF
+6
OFF
+6
HIGH
MID
MID
EQ
+8
OFF
+6
OFF
+6
MID
LOW
FlexFX
LOW
A POST B
A POST B
+8
LOW
10
10
10
8
8
8
6
6
6
4
4
4
2
2
2
0
0
0
A
CROSSFADER
CD TRIGGER
LIMIT
CH 3
CH 4
0
0
OL
OL
-12
+12
OFF
+6
-12
+12
OFF
+6
-12
LEVEL
HIGH
LEVEL
HIGH
2A
3A
4A
2B
3B
4B
SOURCE
SOURCE
SOURCE
OFF
+6
OFF
+6
MID
MID
EQ
EQ
OFF
+6
OFF
+6
FlexFX
LOW
FlexFX
LOW
A POST B
A POST B
10
10
10
10
8
8
8
8
6
6
6
6
4
4
4
4
2
2
2
2
0
0
0
0
B
DJ Features Section
High performance Master Limiter affects both House
and Booth signals. The Limiter is a safety net de-
signed to protect ears and equipment. Under normal
operating conditions, the LIMIT indicator should
only flash occasionally. If you are running gains
high enough to cause hard limiting, faders and tone
controls will not respond as expected. For example,
if you run signal levels 10 dB over the Limit thresh-
old, you must turn signal levels down 10 dB before
you hear a reduction in level. See page Manual-5 for
more details.
3-band Tone Controls with full cut (off to +6 dB) on
each of the four Input Buses. You know what to do
with this!
FlexFX™ assignment allows any combination of the
four Input Buses to be processed by the FlexFX
Loop, regardless of A-side, B-side or Post crossfader
assignment! See page Manual-3 for details
MASTER
0
LEFT / CUE
-20
-10
-7
-4
-2
0
+2
+4
+7
+10
+12
LEVEL
RIGHT / PGM
LEFT / RIGHT
PEAK PROGRAM METER
CUE / PGM
EQ
METER
SENSITIVITY
FlexFX
HOUSE LEVEL
L
10
10
10
BALANCE
4
8
8
8
2
6
6
6
0
BOOTH
LEVEL
4
4
4
2
2
2
EFFECTS
0
0
0
MONO
MONITOR
2
2
4
CUE
6
6
2
CUE
PGM
0
CH 1
CH 2
CH 3
CH 4
PAN
MONO
LEVEL
MP 44
DJ MIXER
AUX IN
4
6
2
8
dB
0
10
AUX A
4
6
2
8
0
10
AUX B
AUX OUT
6
4
2
8
0
10
AUX A
PRE POST MIC
R
6
6
4
8
2
8
10
0
10
AUX B
PRE POST MIC
MP 44
MIXER
POWER
6
8
10
PHONES
Manual-

Advertisement

Table of Contents
loading

Summary of Contents for Rane MP 44

  • Page 1: Quick Start

    QUICK START If you have used just about any DJ mixer on the planet, you will instantly feel at home using the MP 44. Extra care was taken to ensure that controls are where you expect them to be, and operate as you expect them to.
  • Page 2: Input Channels

    RETURN SEND LIGHT PHONO GROUND posts are provided for connecting turntable ground wires. It is very important that each turntable have a LEVEL TRIGGER OUTPUT secure ground connection to the MP 44. COMMERCIAL AUDIO EQUIPMENT 24TJ LISTED MASTER INPUT CH’s 1B, 2B, 3B, and 4B enter via stereo, line-level, unbalanced RCA jacks. Maximum input level is +20 dBu.
  • Page 3: Cleaning Instructions

    The fader assembly must be removed from 2. Remove the bottom cover. the MP 44 for proper cleaning. We recommend any of the fol- 3. Remove the fader screws from the front panel. lowing cleaning solutions: 4.
  • Page 4: Auxiliary Inputs & Outputs

    AUX OUT B PRE • POST • MIC switch sets AUX OUT B source to PRE-Master-Effects, POST-Master-Ef- PRE POST MIC fects or Post-Master-Effects-plus-MIC. Source selection and level control give AUX OUT B the versatility to accom- EFFECTS modate applications ranging from recording to additional Zone output. MP 44 MIXER MONO POWER MASTER MIX PROCESSING The MASTER mix is the point at which all input signals (CH 1 –...
  • Page 5: Headphone Monitor

    0 dB = -10 dBV (more sensitive). The meter is peak responding with a 1 second peak AUX OUT METER hold. SENSITIVITY WARNING MP 44 TO REDUCE THE RISK OF FIRE OR ELE PHONO GROUND MADE IN U.S.A. NOT EXPOSE THIS EQUIPMENT TO RAIN FlexFX RANE CORP.
  • Page 6: Mic Inputs

    This control is a recessed, screw driver adjusted control located on the rear panel to prevent tampering after installation. WARNING AVIS MP 44 TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR MADE IN U.S.A.
  • Page 7: Remote Installation

    REMOTE INSTALLATION Turn the power to the MP 44 off until all connections are made. It is important to ensure that the Remote Ports are not subjected to sustained voltages outside the range of 0 to 5 volts DC or high levels of static.
  • Page 8: Input Block Diagram

    INPUT BLOCK DIAGRAM Manual-...
  • Page 9: Output Block Diagram

    OUTPUT BLOCK DIAGRAM ©Rane Corporation 00 th Ave. W., Mukilteo WA -0 USA TEL --000 FAX -- WEB www.rane.com 106150 Manual-...

Table of Contents